32
Setting the functions for when the unit is linked with the switcher
Set the functions that can be used when there is a link between the unit
and switcher .
Each of the functions needs to be set in advance in SW FUNCTION
menu [42] and SW INPUT menu [43] .
⇒
“Registering the camera numbers that will correspond to the image
inputs of the switcher” (page 31)
⇒
“Enabling or disabling the function for linking with the switcher”
(page 31)
BUSCONT function
Select the bus material of the switcher from the unit .
When the BUSCONT function is enabled, the bus material of the
switcher can be selected in conjunction with camera selection on the
unit .
z
z
When the link setting of a camera number is changed with
AUTO IP menu [37], SWAP IP menu [38], or MANUAL IP menu
[39] or a camera number corresponding to an image input of
the switcher is changed with SW INPUT menu [43], the bus
material of the switcher will not be changed immediately even
if the BUSCONT function is enabled . Press one of the camera
selection buttons [CAMERA SELECT/GROUP SELECT] to make
a selection again .
Note
Enabling or disabling the BUSCONT function
1 .
Press the MENU button .
2 .
Open SW FUNCTION menu [42] .
3 .
Turn the F1 dial to display the “2 . BUSCONT” item .
2.BUSCONT
Off
4 .
Turn the F2 dial to select “On” or “Off”, and then press
the F2 dial to confirm the selection .
On :
Enables the BUSCONT function .
Off :
Disables the BUSCONT function .
z
z
Enabling and disabling the BUSCONT function can be assigned to a
USER button .
Open USER BUTTON menu [35], display one of the “1 . USER1”
to “8 . USER8” items, and set “BUSCONT” .
z
z
When the USER button with “BUSCONT” assigned is pressed, the
operation is as follows .
Button indicator on :
Enables the BUSCONT function .
Button indicator off :
Disables the BUSCONT function .
Setting the switcher bus to control with the BUSCONT
function
When the BUSCONT function is enabled, you can set the switcher
bus to control with a camera selection button [CAMERA SELECT/
GROUP SELECT] on the unit .
1 .
Press the MENU button .
2 .
Open SW FUNCTION menu [42] .
3 .
Turn the F1 dial to display the “3 . BUS” item .
3.BUS
AUX
4 .
Turn the F2 dial to select a setting, and then press the
F2 dial to confirm the setting .
AUX :
The AUX bus of the switcher is the control target .
PVW :
The PVW bus of the switcher is the control target .
PinP :
The PinP bus of the switcher is the control target .
KEY :
The KEY bus of the switcher is the control target .