- 8 (E) -
ENGLISH
Major operating controls and their functions
Function Switches [SW1, SW2, SET UP]
(Factory defaults: SW1 = OFF, SW2 = OFF,
SET UP No.1 = ON, SET UP No.2 to 4 = OFF)
This is used to select the operations of the AW-IF400.
Before changing a setting, the power must be turned off.
SETUP No.3 is the tilt range selector switch which is used
to control the AW-PH400 from the AW-RP605A.
At the ON position, the range is 300 degrees; at the OFF
position, it is 190 degrees. For any other combination, use
the switch at the OFF position.
Functions
SW1 SW2
SET UP
No.1 No.2
No.3
No.4
MODE SET
TILT RANGE
NOT USE
Controlling PH400 from RP605A
OFF OFF ON OFF
ON
(300 deg)
OFF
(190 deg)
OFF
Extending communication distance
between RP400 and PH400
ON
ON OFF OFF
OFF
(Set at RP400)
OFF
Controlling PH350 from RP400
OFF ON OFF ON
OFF
OFF
DC 12 V input connector [DC12V IN]
Connect the AW-PS505A AC adapter (sold separately) to
this socket.
Cable clamp
This is used to clamp the power cable in place and
prevent it from coming loose.
Summary of Contents for AWIF400G - PROTOCOL CONVERTER
Page 21: ... 20 E ENGLISH ...