- 32 -
Connections
6
When the camera and pan/tilt head are to be controlled by the AW-RP505 control panel
for transmitting SDI signals
• Use the supplied camera cable to connect the unit with the convertible camera containing the
plugged-in SDI card (such as the AW-PB504N).
• Use a coaxial cable to connect the SDI card’s SDI OUT connector with the unit’s SDI IN
connector. Adjust the cable to a length at which the pan/tilt head will move smoothly.
• Set controller selection switch SW1 to the right side (RP501), and select the transmission signal
selection setting that supports the SDI card.
• Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN IP/RP
connector with the multiport hub’s PAN/TILT CONTROL OUT connector.
• Use a coaxial cable (BELDEN 8281) to connect the unit’s CAMERA CONTROL IN connector with
the multiport hub’s CAMERA CONTROL OUT connector.
• Use a 10BASE-T straight cable (UTP category 5) to connect the multiport hub’s PAN/TILT
CONTROL IN connector with the controller’s PAN/TILT CONTROL OUT connector.
• Use a coaxial cable (BELDEN 8281) to connect the multiport hub’s CAMERA CONTROL IN
connector with the controller’s CAMERA CONTROL OUT connector.
• Use a coaxial cable to connect the unit’s Pr/SDI OUT connector with the color monitor’s SDI input
connector.
• Check that the pan/tilt head and camera can be controlled by the controller.
Genlock signals must be supplied if
a multiple number of cameras and
pan/tilt heads are to be used.
Multiport hub:
AW-HB505
AC adapter:
AW-PS300A
Color monitor
Coaxial cable
(BELDEN 8281),
max. 666 ft. (200 m)
10BASE-T
(equivalent to
UTP category
5) straight
cable, max.
1640 ft. (500 m)
Coaxial cable (BELDEN 8281),
max. 1640 ft. (500 m)
Coaxial
cable
(BELDEN
8281), max.
33 ft. (10 m)
10BASE-T (equivalent
to UTP category 5)
straight cable, max.
33 ft. (10 m)
Camera cable
(supplied)
Coaxial cable
Multi hybrid control panel:
AW-RP505
DC cable
(UL Type SPT-2 2
!
16 AWG
or UL Type NISPT-2 2
!
16
AWG, to be locally
purchased)