Page 1-41
REGULAR
MAINTENANCE
1
OFF ( ) ON ( )
SERVO
Check Every 140 Hours (Once a Week)
7.
Rechecking the nozzle arrangement
Ensure that the set nozzle is properly arranged. The nozzle arrangement on the transfer head can
be verified by the machine by using the line camera.
1.
Press
UNLOCK
+ Nozl set chk .
•
The transfer head will travel above the line
camera and the verification including the
existence of nozzle will be performed.
∗∗∗∗∗
The set nozzle is arranged wrong :
1.
Turn OFF the servo switch.
2.
Open the safety cover.
3.
Rearrange the nozzle right.
444C-420P
444C-E-MMA01-A05-04