Page 1-83
REGULAR
MAINTENANCE
1
Check Every 6000 Hours (Once a Year)
Notice
Before opening the distributor, ensure that the power of the machine is certainly
OFF.
Remove the 3 wiring connected to the distribution part.
Write down the wiring order not to mistake. The mistaken order will cause the
reverse of the vacuum pump.
5.
Open the distributor.
6.
Remove the vacuum pump, and re-
place it with a new one.
7.
Connect the tube.
8.
Connect the wiring as written down at
step 5.
9.
Fix the vacuum pump by the 2 bolts.
10.
Set the cover.
Checking the vacuum pressure
1-5-1 Cleaning the Lubricating the
Transfer Head 2. Checking the vacuum
pressure
444C-E-MMA01-A09-04
444C-494P