Page 1-32
Check Every 140 Hours (Once a Week)
6.
Remove the nozzle holder from the
transfer head.
Hold the nozzle a little and push it upward.
Keeping it pushed up, turn it to the right.
Pull it out slowly downward.
∗
For pulling the nozzle holder, be careful not to
take off the spring for nozzle cushion.
∗
As the spring for clamp arm holder tends to be
damaged, do not press it too much.
∗
Remove all nozzle holders from the transfer
head in the same procedures.
∗
When the nozzle changer (option) installed
Remove the nozzle from the nozzle
changer.
b. Removing the nozzle from the nozzle holder
1.
Separate the nozzle from the nozzle
holder.
∗
Hold the edge of the nozzle reflector and pull it
out downward the nozzle holder.
∗
The clamp arm may be taken off by pulling the
nozzle sideways.
444C-428P
444C-406E
444C-421P
444C-488P
1
2
3
Nozzle holder
Spring for clamp
arm holder
Clamp arm
Nozzle
1
2
3
444C-422P
444C-E-MMA01-A05-02