Page 1-20
1-3
Check Every 24 Hours (Routine)
1-3-1
Checking the MR Unit (before Operation)
Check the air pressure of MR unit and clean the water receiver.
∗
The MR unit is put at lower right of the machine rear side. This operation is for AR only.
1.
Open the cover at lower right of the
machine rear side.
∗
Remove the screw by using a Philips driver.
2.
Check the air pressure.
Valve operation
∗
Supply air pressure standard
0.49 MPa to 0.79 MPa
∗
Ensure that it is within the standard.
When the air pressure is out of the standard,
adjust it with the valve.
3.
Check the water receiver.
∗
Empty the water.
4.
Close the cover at lower right of the
machine rear side.
∗
Tighten the screw by using the Philips screw.
4U4C-AB00
Tools
Philips driver
Required time
1 minute
AR
BR
444C-401P
Air pressure gauge
1. Unlock
2. Adjust
3. Lock
Valve
444C-402P
Water receiver
444C-E-MMA01-A03-05
∗∗∗∗∗