CM602-L
Reference Manual
1.3 Equipment Specifications
Page 1-12
1.3 Equipment Specifications
1.3.1 Machine Specifications
Item
Specifications
Control system
Microcomputer system
External memory
The data is managed by PT
∗
4
.
Approximately 1 MB is required for a piece of data. (One type per 3.5-inch 2HD floppy disk)
Program data
∗
1
Point count: Max. 10000 points
Machine body
Normal service source: Three-phase 200/220 VAC
±
10 VAC,
Three-phase 380/400/420/480 VAC
±
20 VAC
Frequency: 50/60 Hz
Power source
Power supply for
HUB
∗
3
Single-phase 100 VAC to 240 VAC, Frequency: 50/60 Hz
Machine body
4.0 kVA
Rated capacity
Power supply for
HUB
∗
3
140 VA
Supply air pressure
0.49 MPa to 0.78 MPa (Working air pressure: 0.49 MPa to 0.54 MPa)
Supply air volume
170 L/min (A.N.R.)
Outside dimension
2350 mm (W)
×
2690 mm (D)
×
1430 mm (H)
(Three-color signal tower and color touch panels not included)
Mass of main body
3400
kg
(Standard configuration, excluding 140
kg
of a collectively
changing truck)
Mass
∗
2
Mass of collectively
changing truck
140
kg
(per unit)
Mass of standard
configuration
3960
kg
(One main body and four collectively changing trucks)
Environmental
condition
Temperature: 10
°
C to 35
°
C
Humidity: 25% RH to 75% RH (No condensation)
Transportation and
storage condition
Temperature:
−
20
°
C to 60
°
C
Humidity: 75% RH or less (No condensation)
Altitude
1000 m or less, above sea level
Noise
< 70 dB (A)
∗
1 : The data is created by PT. This machine can modify only some data.
∗
2 : Mass of the main body excluding the optional units
∗
3 : The power supply for HUB is an option. This power supply is required when you wish to
communicate with PT while the main power supply is OFF.
∗
4 : PT (Programming Terminal Support System), which creates and manages the production data.
EJM4A-E-RMA01-A01-00