3.15. Changer Error Code
·
The error code summary of CRS1 changer is as below:
Error Code
Operation
IHMS
Cam gear rotate to HOME position
ICLS
Cam gear rotate to Play Driving position to drive playing tray to STOCK position
ISTK
Move tray drive rack to STOCK position (drive tray to STOCK position)
IPLY
Move tray drive rack to PLAY position (drive tray to PLAY position)
ITOP
Move UD rack R to front direction (raise UD base to top position)
IUDS
After TOP-SW detect, UD rack move to tray 1 position
HOME
After load tray to PLAY position, cam gear move to HOMEAfter unload to STOCK position, cam gear
move to HOME
After all tray close, cam gear go to HOME position
LOAD
Tray move from STOCK to PLAY position
UNLD
Tray move from PLAY to STOCK position
PDRV
Cam gear move from HOME to Play Driving position
UDU
UD base move at up direction (from tray 5 to tray 2)
UDD
UD base move at down direction (from tray 1 to tray 5)
UD1
UD base move to tray 1
F1NG
Fail safe 1 NG (Fail safe 1 unsuccessful then try Fail Safe 2 also unsuccesful)
F2NG
Fail safe 2 NG (Fail safe 2 unsuccessful then try Fail Safe 1 also unsuccesful)