NAME OF EACH PART

Remote Control

Remote Control Signal.

• Make sure it is not obstructed.
• Maximum distance : 10 m.
• Signal received sound.

One short beep or one long beep.

Notes for Remote Control.

• Do not throw or drop.
• Do not get it wet.
• Certain type of fluorescent lamps may affect

signal reception. Consult your dealer.

Do not place the remote control in a location exposed
to direct sunlight, or next to a heating unit, or other
heat  source.

How  to Insert the Batteries

1

Gently press the place marked  OPEN  and slide
the cover towards you.

2

Insert the batteries

– Be sure the direction is correct.

About the batteries

• Can be used for approximately one year.

Observe the following when replacing the batteries

• Replace with new batteries of the same type.
• Do not use rechargeable batteries (Ni-Cd).
• Remove the batteries if the unit is not going to be

used for a long period.

Proper way to operate the remote control in the
case of ceiling/wall mounting.

• Operate the remote control in parallel with the floor.

(See the figure below)

1

Signal Transmitter

2

Operation Display

3

Room Temperature Setting Button
(Illuminating button)

4

Operation Mode Selection Button

5

Sleep Mode Operation Button
(Illuminating button)

6

 Timer Setting Button

7

Timer Selection Button

8

OFF/ON Button
(Illuminating button)

9

Fan Speed Selection Button

0

Auto Airflow Direction Button

!

Timer Set/Cancel Button

@

 Manual Airflow Direction Selection Button

#

Reset Point
(Press with fine-tipped object to clear the memory)

Cooling Model

Heat Pump Model

H

H

• The signal changes as shown in the figure below.

It means that the receiving conditions are bad and
the signal can not be controlled properly.

O.K.

OUT

(Fig. 2)

(Fig. 1) Horizontal Level

HOW TO OPERATE

To start the operation

• Press 

1

.

• POWER indicator (green) on the indoor unit will light up.
• To stop, press once more.

Setting Mode

• Press 

2

 to select:-

Cooling Model

AUTO

– Automatic Operation

COOL

– Cooling Operation

DRY

– Soft Dry Operation

FAN

– Air Circulation Operation

Heat Pump Model

AUTO

– Automatic Operation

HEAT

– Heating Operation

COOL

– Cooling Operation

DRY

– Soft Dry Operation

PREPARATION BEFORE OPERATION

Indoor Unit

1

Connect the power supply cord to an independent
power supply.

Setting Temperature

• Press 

3

 to increase or decrease the temperature.

• The temperature can be set between 16°C ~ 30°C
• Recommended temperature:

• During 

AUTO

 Operation, press 

3

 to select:-

Operation with 2°C higher than the standard
temperature.

Operation with the standard temperature.

Operation with 2°C lower than the standard
temperature.

Standard Temperature

Cooling Model

• Once the Automatic Operation is selected, the indoor

temperature sensor operates automatically to select
the desired operation mode with Cooling or Soft Dry.

• After the operation mode has been selected, the

mode does not change.

Heat Pump Model

• At the beginning of the automatic operation, Heating,

Cooling or Soft Dry is automatically selected according
to the indoor temperature.

• After the operation mode has been selected, the

mode does not change.

Operation

Cooling

Soft Dry

Standard

temperature

25°C

22°C

Indoor

temperature

23°C

Operation

Cooling

Soft Dry

Heating

Standard

temperature

25°C

22°C

21°C

Indoor

temperature

23°C

20°C

Cooling Model

COOL –>   26°C ~ 28°C

DRY

–>       1°C ~   2°C
lower than the
room temperature

Heat Pump Model

COOL –>   26°C ~ 28°C

DRY

–>       1°C ~   2°C
lower than the
room temperature

HEAT –> 20°C ~ 24°C

Operation Details

COOL – Cooling Operation

To set the room temperature at your preference
cooling comfort.

AUTO – Automatic Operation

Sense indoor temperature to select the optimum
mode.

Temperature is not displayed on the remote control
during AUTO operation.

DRY – Soft Dry Operation

A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.

During Soft Dry operation, the indoor fan operates at
Low Fan Speed.

HEAT – Heating Operation

(for Heat Pump Model only)

Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.

Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.

FAN – Air Circulation Operation

(for Cooling Model only)

Heated air rises and collects at the top of the room.
The air circulation circulates the heated air downward,
thus increasing heating effectiveness. When the unit
is installed floor mounted, you should set the
temperature higher than that of ceiling mounted.

At ceiling mounted

At floor mounted

1

36

CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5