NAME OF EACH PART

Remote Control

Remote Control Signal.

• Make sure it is not obstructed.
• Maximum distance : 10 m.
• Signal received sound.

One short beep or one long beep.

Notes for Remote Control.

• Do not throw or drop.
• Do not get it wet.
• Certain type of fluorescent lamps may affect

signal reception. Consult your dealer.

CHECK

TEMP

AUT

AUTO

ON

OFF

AUT

AUTO

HEA

HEAT

DR

DRY FAN

AN

COOL

COOL

FAN

AN

AUT

AUTO

RESET CLOCK

MODE

SLEEP

ECONOMY

FAN SPEED

AIR SWING

OFF

CANCEL

ON

SET

1

2

3

TIMER

OFF/ON

POWERFUL

#

!

$

%

^

$

*

&

3

5

8

7

9

0

6

4

(

AUT

AUTO

2

1

How  to Insert the Batteries

1

Slide down the remote control cover completely

2

Insert the batteries

– Be sure the direction is correct
– 12.00 at display - flashing
• Set the current time (CLOCK) immediately to

prevent battery exhaustion.

About the batteries

• Can be used for approximately one year.

Observe the following when replacing the
batteries

• Replace with new batteries of the same type.
• Do not use rechargeable batteries (Ni-Cd).
• Remove the batteries if the unit is not going to be

used for a long period.

1

Signal Transmitter

2

Operation Display

3

Powerful Mode Operation Button

4

Room Temperature Setting Button
(self-illuminating button)

5

Operation Mode Selection Button

6

Economy Mode Operation Button

7

Vertical Airflow Direction Button

8

ON-Timer Button

9

OFF-Timer Button

0

Reset Point
(Press with fine-tipped object to clear the memory)

!

OFF/ON Button
(self-illuminating button)

@

Sleep Mode Operation Button

#

Fan Speed Selection Button

$

Horizontal Airflow Direction Button

%

Timer Set Button

^

Timer Cancellation Button

&

Time-Setting Button

*

Clock Button

(

Remote Control Cover

CH

EC

K

T

AUT

O

ON

OFF

AUT

OHEA

T

DR

Y FA

N

COOL

FA

N

AUT

O

AUT

O

RE

SET

CLO

CK

AIR

 S

W

IN

G

OFF

CANCEL

1

2

3

TIMER

POWERFUL

AUT

O

MANUAL

ECONOMY

SLEE

P

ON

SET

FAN SPEED

MODE

2

1

1.5V

1.5V

PREPARATION BEFORE OPERATION

Indoor Unit

1

Connect the power supply cord to an independent
power supply

2

Open the front panel

3

Remove the air filters

4

Fit the air purifying filters in place

5

Insert the air filters

6

Close the front panel

Remote Control

– To set the current time

1

Press 

1

.

2

Then press 

2

 to increase or decrease the time.

3

Press 

1

 again.

Set time at display will light up.

RESET CLOCK

FAN SPEED

AIR SWING

OFF

CANCEL

ON

SET

1

2

3

TIMER

1

2

6

2

1

4

5

3

Setting Temperature

• Press 

3

 to increase or decrease the temperature.

• The temperature can be set between 16°C ~ 30°C.
• Recommended temperature:

• During 

AUTO

 Operation, press 

3

 to select:-

Operation with 2°C higher than the standard
temperature.

Operation with the standard temperature.

Operation with 2°C lower than the standard
temperature.

Standard Temperature

Cooling Model

• Once the Automatic Operation is selected, the indoor

temperature sensor operates automatically to select
the desired operation mode with Cooling or Soft Dry.

• After the operation mode has been selected, the

mode does not change.

Heat Pump Model

• At the beginning of the automatic operation, Heating,

Cooling or Soft Dry is automatically selected according
to the indoor temperature.

• The operation mode changes every hour, when

necessary.

Operation

Cooling

Soft Dry

Standard

temperature

25°C

22°C

Indoor

temperature

23°C

HOW TO OPERATE

To start the operation

• Press 

1

.

• POWER indicator (green) on the indoor unit will light

up.

• To stop, press once more.

Setting Mode

• Press 

2

 to select:-

Cooling Model

AUTO

– Automatic Operation

COOL

– Cooling Operation

DRY

– Soft Dry Operation

FAN

– Air Circulation Operation

Heat Pump Model

AUTO

– Automatic Operation

HEAT

– Heating Operation

COOL

– Cooling Operation

DRY

– Soft Dry Operation

Operation

Cooling

Soft Dry

Heating

Standard

temperature

25°C

22°C

21°C

Indoor

temperature

23°C

20°C

Heat Pump Model

COOL – 26°C ~ 28°C
DRY

–  1°C ~   2°C

lower than the

room temperature

HEAT – 20°C ~ 24°C

Cooling Model

COOL – 26°C ~ 28°C
DRY

–     1°C ~   2°C
lower than the
room temperature

OFF

ON

HE

A

HEA

T

DR

DR

Y F

AN

AN

CO

OL

COOL

TE

M

P

AU

T

AUT

O

AU

T

AUT

O

FA

N

AN

AU

T

AUT

O

AIR

 S

W

ING

1

2

OF

F/O

N

POWERFUL

ECONOMY

SLE

EP

ON

FAN

 SPE

ED

MO

DE

AU

T

AUT

O

2

3
5

1

6
4

Summary of Contents for CS-A24

Page 1: ...h off and unplug the power supply Caution This sign warns of injury Do not pull the cord to disconnect the plug Do not wash the unit with water Do not use for other purposes such as preservation Do not use any combustible equipment at airflow direction Do not sit or place anything on the outdoor unit Switch off the power supply before cleaning Ventilate the room regularly Pay attention as to wheth...

Page 2: ...r supply 2 Open the front panel 3 Remove the air filters 4 Fit the air purifying filters in place 5 Insert the air filters 6 Close the front panel Remote Control To set the current time 1 Press 1 2 Then press 2 to increase or decrease the time 3 Press 1 again Set time at display will light up RESET CLOCK FAN SPEED AIR SWING OFF CANCEL ON SET 1 2 3 TIMER 1 2 6 2 1 4 5 3 Setting Temperature Press 3 ...

Page 3: ...ion press 4 OFF TIMER Operation To stop the air conditioner operation automatically Press 5 to set the operation Press 2 to increase or decrease the time Then press 3 To cancel this operation press 4 Timer Mode Operation Details When the ON Timer is set operation will start before the actual set time This is to enable the room temperature reaches the set temperature at the set time Once the ON Tim...

Page 4: ...oling capacity decreases Foul odour is emitted Heat Pump Model COOL 8 C or above HEAT 14 C or above Cooling Model COOL 8 C or above Heat Pump Model COOL operation with 30 C set temperature Cooling Model FAN operation Fulcrum Protruding portion on indoor unit 2 Remove the air filters 1 Raise the front panel Catechin Air Purifying Filter Solar Refreshing Deodorizing Filter HELPFUL INFORMATION Auto O...

Page 5: ... COOL DRY operation moisture in the air condenses into water on the cool surface of outdoor unit piping that causes dripping This is to melt the frost which has accumulated on the outdoor unit defrosting operating This will take no longer than about 12 minutes Water drips from the outdoor unit Wait until this operation ends the power indicator will light up Frost will accumulates on the outdoor un...