background image

Pre-season Inspection

Is the discharged air cold/warm?

Operation is normal if 15 minutes after the start of
operation, the difference between the air intake and
outlet vents temperature is:-

Are the air intake or outlet vents of the indoor or
outdoor units obstructed?

Are the remote control batteries weak?

If the remote control display appears weak, replace
the batteries.

When the Air Conditioner is Not Used
for an Extended Period of Time

1

To dry the internal parts of the indoor unit, operate
the unit for 2 - 3 hours using:-

2

Turn off the power supply and unplug.
Note: If the unit is not switched off by the remote
control, it will start operating when you plug in
(because the unit is equipped with Auto Restart
Control).

3

Remove the remote control batteries.

Recommended Inspection

• After used over several seasons, the unit will

become dirty and thus decreases the unit’s
performance. Depending on the operation
conditions, a dirty unit may produce odour and dust
may pollute dehumidification system. Therefore, a
seasonal inspection is recommended in addition to
regular cleaning. (Consult an authorized dealer).

CARE AND MAINTENANCE

Cleaning the Indoor Unit and Remote
Control

• Wipe gently with a soft, dry cloth.
• Do not use water hotter than 40˚C or polishing fluid

to clean the unit.

Cleaning the Air Filter

(Recommendation:- If the unit is operated in a dusty
environment, clean the filters every two weeks,
continuous use of this dirty filters will reduce cooling
or heating efficiency)

1

Remove dirt using a vacuum cleaner.

2

Wash back of the air filter with water.

3

If badly soiled, wash it with soap or a mild household
detergent.

4

Let it dry and reinstall it.
Be sure the “FRONT” mark is facing you.

*

Damaged air filter.
Consult the nearest authorized dealer.
Part No.: CWD001049.

• Do not use benzene, thinner, scouring powder or

clothes soaked in caustic chemical to clean the unit.

Cleaning the Front Panel

(Must be removed before washing)

1

Raise the front panel higher than the horizontal and
pull to remove it.

2

Gently wash with water and a sponge.
• Do not press the front panel too hard when washing.
• When use kitchen cleaning fluid (neutral detergent),

rinse throughly.

• Do not dry the front panel under direct sunlight.

3

To fix the front panel, raise the front panel
horizontally, match the protruding portion on the
indoor unit to the fulcrum and push into place.

Air Purifying Filters

Solar Refreshing Deodorizing Filter

• Used to remove unpleasant odour and deodorize

the air in the room.

• Reusable.
• Vacuum, place under direct sunlight for 6 hours and

fit it back in place.
(Recommended : every 6 months)

Catechin Air Purifying Filter

• The filter is coated with catechin to prevent growth

of bacteria and viruses.

• Reusable.
• Vacuum and fit it back in place

(Recommended : every 6 months)

Recommended to change these filters every 3 years.
Do not reuse damaged filters.
Consult the nearest authorized dealer to purchase a
new filter.
Catechin Air Purifying Filter No.: CZ-SF70P
Solar Refreshing Deodorizing Filter No.: CZ-SFD70P

If you operate the air conditioner with dirty filters:-
– Air is not purified
– Cooling capacity decreases
– Foul odour is emitted

Heat Pump Model

COOL – 8°C or above
HEAT – 14°C or above

Cooling Model

COOL – 8°C or above

Heat Pump Model

COOL operation with 30°C
set temperature

Cooling Model

FAN operation

Fulcrum

Protruding portion on indoor unit

2

Remove the air filters

1

Raise the

front panel

Catechin Air
Purifying Filter

Solar Refreshing
Deodorizing Filter

HELPFUL INFORMATION

Auto Operation Button

Automatic Operation

• If the remote control fails to function or has been

misplaced, press the Auto Operation button to start
the Automatic operation.

• The Automatic operation will be activated

immediately once the Auto operation button is
pressed. However, temperature cannot be adjusted
in this operation.

• The power indicator on the indoor unit will blink until

the operation mode is selected automatically.

• To cancel this operation, press once more.

Remote Control Signal Receiving Sound

• To switch off the beep (Signal Receiving Sound),

press the Auto Operation button for 10 seconds
continuously or longer.

“Beep”, “beep” sound will be heard at the tenth
seconds.

Note: “Beep” sound will be heard at the fifth

seconds;
However please press continuously until you
heard “beep”, “beep” sound.

• Repeat the above steps if you want to switch on the

Signal Receiving Sound.

(This is for Servicing purposes only.)

Note: If you press this button continuously for 5 to 10
seconds, Test Run operation will be performed.
A “beep” sound will be heard at the fifth seconds
indicating the Test Run starts to operate.

POWERFUL

POWERFUL

ECONOMY

ECONOMY

POWER

POWER

TIMER

TIMER

SLEEP

SLEEP

POWERFUL

POWERFUL

ECONOMY

ECONOMY

POWER

POWER

TIMER

TIMER

SLEEP

SLEEP

Auto Restart Control

• If power is resumed after a power failure, the

operation will restart automatically after 3 - 5 1/2
minutes.

• Operation will be restarted automatically under the

previous operation mode and airflow direction when
power is resumed as the operation is not stopped
by the remote control.

Timer Setting

• When power failure occurs, the timer setting will be

cancelled. Once power is resumed, reset the timer.

Thunder and Lightning

• This air conditioner is equipped with a built-in surge

protective device. However, in order to further
protect your air conditioner from being damaged by
abnormally strong lightning activity, you may switch
off the main power supply and unplug from power
socket.

ENERGY SAVING AND OPERATION
HINTS

Setting the Temperature

• Approximately 10% of electricity can be saved.
• Set the temperature higher or lower than the

desired temperature.

Cooling Model

Cooling Operation : 1°C higher

Heat Pump Model

Cooling Operation : 1°C higher
Heating Operation : 2°C lower

Air Filters and Air Purifying Filters

• Clean the air filters every 2 weeks and the Air

Purifying Filters every 6 months.

• Dirty filters may reduces cooling or heating

efficiency.

Keep All Doors and Windows Closed

• Otherwise, cooling or heating performance will be

reduced and electricity cost is wasted.

Outdoor Unit

• Do not block the air outlet vents. Otherwise, it will

lower the cooling or heating performance.

Timer and Sleep Mode

• To prevent wastage of electricity, use sleep mode

when sleeping or Timer when going out.

Avoid Direct Sunlight

• Keep curtains or drapes closed to avoid direct

sunlight during cooling operation.

• Raise the front panel and press.

Summary of Contents for CS-A24

Page 1: ...h off and unplug the power supply Caution This sign warns of injury Do not pull the cord to disconnect the plug Do not wash the unit with water Do not use for other purposes such as preservation Do not use any combustible equipment at airflow direction Do not sit or place anything on the outdoor unit Switch off the power supply before cleaning Ventilate the room regularly Pay attention as to wheth...

Page 2: ...r supply 2 Open the front panel 3 Remove the air filters 4 Fit the air purifying filters in place 5 Insert the air filters 6 Close the front panel Remote Control To set the current time 1 Press 1 2 Then press 2 to increase or decrease the time 3 Press 1 again Set time at display will light up RESET CLOCK FAN SPEED AIR SWING OFF CANCEL ON SET 1 2 3 TIMER 1 2 6 2 1 4 5 3 Setting Temperature Press 3 ...

Page 3: ...ion press 4 OFF TIMER Operation To stop the air conditioner operation automatically Press 5 to set the operation Press 2 to increase or decrease the time Then press 3 To cancel this operation press 4 Timer Mode Operation Details When the ON Timer is set operation will start before the actual set time This is to enable the room temperature reaches the set temperature at the set time Once the ON Tim...

Page 4: ...oling capacity decreases Foul odour is emitted Heat Pump Model COOL 8 C or above HEAT 14 C or above Cooling Model COOL 8 C or above Heat Pump Model COOL operation with 30 C set temperature Cooling Model FAN operation Fulcrum Protruding portion on indoor unit 2 Remove the air filters 1 Raise the front panel Catechin Air Purifying Filter Solar Refreshing Deodorizing Filter HELPFUL INFORMATION Auto O...

Page 5: ... COOL DRY operation moisture in the air condenses into water on the cool surface of outdoor unit piping that causes dripping This is to melt the frost which has accumulated on the outdoor unit defrosting operating This will take no longer than about 12 minutes Water drips from the outdoor unit Wait until this operation ends the power indicator will light up Frost will accumulates on the outdoor un...

Reviews: