 Indoor Unit

 

 Outdoor Unit

OFF/ON

POWER  TIMER

 

 

 

CS-C45FFH

 

 

CU-C45FFH

COOLING

3N~(3-Phase) 380V - 415V, 50Hz

 Power/Current

[W]

4710 - 4800

[A]

8.40 - 8.40

 Refrigerant

[k

g

]

R22

 

2.40

 Cooling Capacity

[

kW]

12.0 - 12.5

 Noise Level

JIS C 9612 [<70 dB(A)]

[

dB(A)]

  

53

Conditions 1m Distance Max. cooling

57

 Air Circulation

[m

3

/min.]

27.0

 Product Weight

[k

g

]

  

52

88

 Dimensions (H × W × D)

[mm]

  

1880 × 600 × 350

1175 

× 900 × 320

Ambient Temperature

[

°C]

18

 - 43

Test conditions 
1.  Cooling:  Indoor  Dry Bulb Temp. (°C) 27 

Outdoor  Dry Bulb Temp.  (°C) 

35

                   

Wet Bulb Temp. (°C) 19 

 

Wet Bulb Temp.  (°C) 

24

2.  Standard piping length:7.5 m(Includes Indoor Unit piping length).
3.  Air filter is attached.

Model

PRODUCT SPECIFICATION

F566276_EN.indd   8

2008-12-16   10:09:18

Summary of Contents for CS-C45FFH

Page 1: ...oner CS C45FFH CU C45FFH ENGLISH Before operating the unit read these operating instructions thoroughly and keep them for future reference CONTENTS Safety Precautions 2 Product Overview 3 How to Operate 5 Care Cleaning 7 Product Specification 8 ...

Page 2: ... Bulb Temperature Indoor Outdoor DBT WBT DBT WBT Maximum Temperature 32 23 43 26 Minimum Temperature 21 15 21 15 Remove the cover of the outdoor unit before operating Use specified supply cord If the supply cord is damaged or needed to be replaced it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard Remove the batteries of remote c...

Page 3: ...and Indicator Panel Signal receiving Air intake Air filter n About To turn off or turn on the air conditioner Operation mode temperature fan speed and OFF ON timer should be set by remote control OFF ON operation button Auto OFF ON Button To operate the unit if the remote control is misplaced or malfunctioning Action Operation mode Press once Automatic Operation Press until beep sound Cooling Oper...

Page 4: ...ay interfere with signal transmission Consult your dealer If the display is chaotic or can not be adjusted use a screwdriver to short the two terminals to reset the remote control to the original set by manufacturer Remote Control Preparation n About Remote Control Signal Insert batteries AAA or R03 The batteries can be used for approximately 1 year Remove the batteries if the unit is not to be us...

Page 5: ... to prevent sunlight and heat from coming in Hint The unit will automatically select the operation mode according to the room temperature Once the operation mode is selected the unit will operate at the standard setting temperature as shown Room temperature Operation mode Standard setting temperature 23 C above Cool 25 C Below 23 C Dry 22 C The operation mode judging temperature and standard setti...

Page 6: ...ly by using either ON or OFF timer Hints Troubleshooting l POWER indicator is blinking 30 minutes before ON timer is activated ä The unit is determining the operation mode by sensing the room temperature This happens when it has been set to AUTO operation mode l The timer indicator of the indoor unit will light up during the timer operation l To cancel either the ON or OFF timers press If you pres...

Page 7: ... use benzene thinner or scouring powder Use soaps or neutral household detergent pH7 only Do not use water with temperature higher than 40 C n Pre season Inspection n Preparation for extended Non operation INDOOR UNIT Wipe gently l Clean the filter regularly as dirty filters will cause unpurified air low cooling capacity unpleasant smells and higher energy consumption l The unit will become dirty ...

Page 8: ...nditions 1m Distance Max cooling 57 Air Circulation m3 min 27 0 Product Weight kg 52 88 Dimensions H W D mm 1880 600 350 1175 900 320 Ambient Temperature C 18 43 Test conditions 1 Cooling Indoor Dry Bulb Temp C 27 Outdoor Dry Bulb Temp C 35 Wet Bulb Temp C 19 Wet Bulb Temp C 24 2 Standard piping length 7 5 m Includes Indoor Unit piping length 3 Air filter is attached Model PRODUCT SPECIFICATION F5...

Page 9: ...g operation Circuit breaker switches off frequently Water foreign particles have entered the Remote Control Power cord becomes unnaturally warm Water leak from Indoor unit Switches or buttons are not functioning properly NON SERVICEABLE CRITERIAS F0812 3 F566276 F566276_EN_back indd 22 2008 12 16 10 07 56 ...