background image

4

   PRODUCT OVERVIEW & OPERATIONS

  PRODUCT OVERVIEW & OPERATIONS

Front panel

Receiver

Auto OFF/ON button

•  Used when remote control is misplaced 

or malfunction.

Action

Mode

Press once.

Auto

Press and hold until 1 beep 

is heard, then release.

Cooling

Press and hold until 1 beep 

is heard, then release. 

Press again until 2 beeps, 

then release.

Heating

Press the button to turn off.

INDICATOR

e-ion AIR PURIFYING SYSTEM

 

Do not touch during operation

e-ion 

fi

 lters

Active e-ion Power 

Module

Active e-ion Generator

Maximum distances:  8m

Remote control 

display

TO TURN ON OR OFF THE UNIT

•  Please be aware of the OFF indication on the remote control 

display to prevent the unit from starting / stopping improperly.

 

TO SET TEMPERATURE

• Selection range: 16

˚

C ~ 30

˚

C.

•  Operating the unit within the recommended temperature could 

induce energy saving.

HEAT mode : 20

˚

C ~ 24

˚

C.

COOL mode : 26

˚

C ~ 28

˚

C.

DRY mode : 1

˚

C ~ 2

˚

C lower than room temperature.

TO SELECT OPERATION MODE

AUTO mode - For your convenience

•  Unit selects operation mode every 30 minutes according to 

temperature setting, outdoor and room temperature. During 

operation mode selection the power indicator blinks.

HEAT mode - To enjoy warm air

•  Unit takes a while to warm up. The power indicator blinks during 

this operation.

COOL mode - To enjoy cool air
DRY mode - To dehumidify the environment

•  Unit operates at low fan speed to give a gentle cooling operation.

Horizontal air

fl

 ow 

direction louver

• Manually 

adjustable.

Vertical air

fl

 ow 

direction louver

•  Do not adjust 

by hand.

F565726.indd   4

F565726.indd   4

6/7/2007   12:26:11 PM

6/7/2007   12:26:11 PM

Summary of Contents for CS-E12GKR

Page 1: ... Industrial Site 40300 Shah Alam Selangor Malaysia 2007 Panasonic HA Air Conditioning M Sdn Bhd 11969 T All rights reserved Unauthorized copying and distribution is a violation of law F565726 QUICK GUIDE QUICK GUIDE Before operating the unit read these operating instructions thoroughly and keep them for future reference Before operating the unit read these operating instructions thoroughly and kee...

Page 2: ...lfunction of the remote control Outdoor Unit Do not sit or place anything on the indoor or outdoor unit Do not touch the sharp aluminium fin Ensure that the drainage pipe is connected properly Otherwise leakage may occur After long periods of use make sure the installation rack is not damaged Indoor Unit Do not install remove and reinstall the unit by yourself improper installation will cause leak...

Page 3: ...LE OF CONTENTS TABLE OF CONTENTS NOTE NOTE The illustrations in this manual are for explanation purposes only and may differ from the actual unit It is subjected to change without notice for future improvement SAFETY PRECAUTIONS 2 REGULATORY INFORMATION 3 PRODUCT OVERVIEW OPERATIONS 4 5 CARE CLEANING 6 TROUBLESHOOTING 7 QUICK GUIDE BACK COVER ENVIRONMENTAL REQUIREMENTS Battery Disposal The batteri...

Page 4: ...play to prevent the unit from starting stopping improperly TO SET TEMPERATURE Selection range 16 C 30 C Operating the unit within the recommended temperature could induce energy saving HEAT mode 20 C 24 C COOL mode 26 C 28 C DRY mode 1 C 2 C lower than room temperature TO SELECT OPERATION MODE AUTO mode For your convenience Unit selects operation mode every 30 minutes according to temperature sett...

Page 5: ... ON or OFF the unit at a preset time Select ON or OFF timer Set the time Confirm To cancel ON or OFF timer press or then press When ON Timer is set the unit may start earlier up to 30 minutes before the actual set time in order to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Remo...

Page 6: ...ease consult your nearest dealer for seasonal inspection ALUMINIUM FIN ALUMINIUM FIN CAUTION Switch off the power supply before cleaning Do not touch the aluminium fin sharp part may cause injury FOR SEASONAL INSPECTION AFTER EXTENDED FOR SEASONAL INSPECTION AFTER EXTENDED NON USE NON USE Checking of remote control batteries No obstruction at air inlet and air outlet vents After 15 minutes of oper...

Page 7: ... stops occasionally during automatic fan speed setting This helps to remove the surrounding odours Operation is delayed a few minutes after restart The delay is a protection to the unit s compressor Outdoor unit emits water steam Condensation or evaporation occurs on pipes Timer indicator is always on The timer setting repeats daily once set Power indicator blinks during operation and the indoor f...

Page 8: ...mote Control Preparation Remote Control Preparation Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global F565726 Printed in Malaysia OFTH0706 01 QUICK GUIDE QUICK GUIDE 1 Press and pull out 2 Insert AAA or R03 batteries can be used 1 year 3 Press CLOCK 4 Set time 5 Confirm 6 Close the cover ...

Reviews: