   CARE & CLEANING

  CARE & CLEANING

   e-ion FILTERS

  

e-ion 

FILTERS

• Clean the 

fi

 lters regularly.

• Wash/rinse the 

fi

 lters gently with water 

to avoid damage to the 

fi

 lter surface.

• Dry the 

fi

 lters thoroughly under 

the shade, away from 

fi

 re or direct 

sunlight.

•  Replace any damage 

fi

 lter. 

ACTIVE e-ion GENERATOR

ACTIVE e-ion GENERATOR

FRONT PANEL

FRONT PANEL

Raise and pull to remove. Wash 

gently and dry.

Remove

Remove

WASHING  INSTRUCTIONS

WASHING  INSTRUCTIONS

•  Do not use benzene, thinner or scouring powder.
•  Use only soap (  pH7) or neutral household detergent.
•  Do not use water hotter than 40°C.

ACTIVE e-ion POWER MODULE

ACTIVE e-ion POWER MODULE

Clean with dry cotton bud.

• Active e-ion generator 

cleaning is recommended 

every 6 months.

INDOOR UNIT

INDOOR UNIT

Wipe the unit gently with a soft, 

dry cloth.

  HINTS

 HINTS

• Clean the 

fi

 lter regularly for best performance and to 

reduce power consumption.

•  Please consult your nearest dealer for seasonal 

inspection.

ALUMINIUM FIN

ALUMINIUM FIN

CAUTION

 

Switch off the power supply before cleaning.

 

Do not touch the aluminium 

fi

 n, sharp part may cause injury.

FOR SEASONAL INSPECTION AFTER EXTENDED 

FOR SEASONAL INSPECTION AFTER EXTENDED 
NON-USE

NON-USE

•  Checking of remote control batteries.
•  No obstruction at air inlet and air outlet vents.
•  After 15 minutes of operation, it is normal to have the 

following temperature difference between air inlet and air 

outlet vents: 

Cooling: 

 8°C  

Heating:  

 14°C

NON SERVICEABLE CRITERIAS

NON SERVICEABLE CRITERIAS

TURN OFF POWER SUPPLY then CALL Authorized 

Distributor under the following conditions:
•  Abnormal noise during operation.
•  Water/foreign particles have entered the remote control.
•  Water leaks from Indoor unit.
•  Circuit breaker switches off frequently.
•  Power cord becomes unnaturally warm.
•  Switches or buttons are not functioning properly.

FOR EXTENDED NON-USE

FOR EXTENDED NON-USE

•  Activate heat mode for 2~3 hours to thoroughly dry the unit.
•  Turn off the power supply.
•  Remove the remote control batteries.

F565726.indd   6

F565726.indd   6

6/7/2007   12:26:15 PM

6/7/2007   12:26:15 PM

Summary of Contents for CS-E12GKR

Page 1: ... Industrial Site 40300 Shah Alam Selangor Malaysia 2007 Panasonic HA Air Conditioning M Sdn Bhd 11969 T All rights reserved Unauthorized copying and distribution is a violation of law F565726 QUICK GUIDE QUICK GUIDE Before operating the unit read these operating instructions thoroughly and keep them for future reference Before operating the unit read these operating instructions thoroughly and kee...

Page 2: ...lfunction of the remote control Outdoor Unit Do not sit or place anything on the indoor or outdoor unit Do not touch the sharp aluminium fin Ensure that the drainage pipe is connected properly Otherwise leakage may occur After long periods of use make sure the installation rack is not damaged Indoor Unit Do not install remove and reinstall the unit by yourself improper installation will cause leak...

Page 3: ...LE OF CONTENTS TABLE OF CONTENTS NOTE NOTE The illustrations in this manual are for explanation purposes only and may differ from the actual unit It is subjected to change without notice for future improvement SAFETY PRECAUTIONS 2 REGULATORY INFORMATION 3 PRODUCT OVERVIEW OPERATIONS 4 5 CARE CLEANING 6 TROUBLESHOOTING 7 QUICK GUIDE BACK COVER ENVIRONMENTAL REQUIREMENTS Battery Disposal The batteri...

Page 4: ...play to prevent the unit from starting stopping improperly TO SET TEMPERATURE Selection range 16 C 30 C Operating the unit within the recommended temperature could induce energy saving HEAT mode 20 C 24 C COOL mode 26 C 28 C DRY mode 1 C 2 C lower than room temperature TO SELECT OPERATION MODE AUTO mode For your convenience Unit selects operation mode every 30 minutes according to temperature sett...

Page 5: ... ON or OFF the unit at a preset time Select ON or OFF timer Set the time Confirm To cancel ON or OFF timer press or then press When ON Timer is set the unit may start earlier up to 30 minutes before the actual set time in order to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Remo...

Page 6: ...ease consult your nearest dealer for seasonal inspection ALUMINIUM FIN ALUMINIUM FIN CAUTION Switch off the power supply before cleaning Do not touch the aluminium fin sharp part may cause injury FOR SEASONAL INSPECTION AFTER EXTENDED FOR SEASONAL INSPECTION AFTER EXTENDED NON USE NON USE Checking of remote control batteries No obstruction at air inlet and air outlet vents After 15 minutes of oper...

Page 7: ... stops occasionally during automatic fan speed setting This helps to remove the surrounding odours Operation is delayed a few minutes after restart The delay is a protection to the unit s compressor Outdoor unit emits water steam Condensation or evaporation occurs on pipes Timer indicator is always on The timer setting repeats daily once set Power indicator blinks during operation and the indoor f...

Page 8: ...mote Control Preparation Remote Control Preparation Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global F565726 Printed in Malaysia OFTH0706 01 QUICK GUIDE QUICK GUIDE 1 Press and pull out 2 Insert AAA or R03 batteries can be used 1 year 3 Press CLOCK 4 Set time 5 Confirm 6 Close the cover ...

Reviews: