8
To learn more...
Operation mode
AUTO :
During operation mode selection the POWER indicator blinks.
• Unit selects operation mode every 10 minutes according to setting temperature and room temperature.
HEAT :
Unit takes a while to warm up. The POWER indicator blinks at the initial stage of this operation.
COOL:
Provides ef
fi
cient comfort cooling to suit your needs.
DRY :
Unit operates at low fan speed to give a gentle cooling operation.
nanoe-G in-
fi
lter deactivation
Depending on the unit’s accumulated operation time, nanoe-G in-
fi
lter deactivation may activate only once a day after
the unit turned off.
To remove the moisture left in the internal parts, the fan will operate for 30 minutes with
fl
ap opened slightly. This
process only applicable when the unit is operated in COOL/DRY mode before turned off. Then, nanoe-G deactivates
viruses/bacteria on the
fi
lter for 2 hours with fan stopped and
fl
ap closed.
Do not turn off the power supply during this operation. After power failure, this operation will not resume.
ECONAVI
Note
AIR SWING
When manual AIR SWING is selected,
the ECONAVI operations will be
cancelled.
The unit will start to initialise
(for approximately 1 minute)
The human activity sensor
and the sunlight sensor will
start to detect.
Human activity sensor operation
Low activity
Normal activity
Human
Mode
Set
temperature
High activity
Absent
ECONAVI
; Detecting human presence and activity, the unit controls room temperature to save energy.
HEAT
COOL/DRY
* During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached.
** During human absence, maximum fan speed for COOL/DRY mode is medium fan.
Low activity
Human
Mode
Precise control of temperature during low activity to maximise energy saving.
Set
temperature
COOL/DRY
ECONAVI
+2°C /
+4°F
+1°C /
+2°F
-2°C /
-4°F
-2°C /
-4°F
ECONAVI take advantage of the human nature that
human being takes time to feel the temperature rise
during low activity level; the unit adjusts temperature
to maximise energy saving without sacrificing the
comfort.
Sunlight Sensor operation
Set
temperature
HEAT
COOL/DRY
ECONAVI
; Detecting sunlight intensity, the unit adjust temperature to save energy.
Ambient condition
Mode
+1°C /
+2°F
-1°C /
-2°F
-1°C /
-2°F
ECONAVI is activated,
the unit maintains set
temperature until a high
sunlight intensity is detected.
The sunlight sensor detects
sunlight intensity during
weather or day/night
changes, and the unit adjusts
temperature.
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.