56
15.4. Error Codes Table
Abnormality or Protection Control
Abnormality
Judgement
Protection
Operation
Problem
Check Location
Diagnosis
Display
H00
No memory of failure
—
Normal operation
—
—
H11
Indoor / outdoor abnormal
communication
After operation for
1 minute
Indoor fan only
operation can start
by entering into
force cooling
operation
• Indoor / outdoor
communication not
establish
• Indoor / outdoor wire
terminal, indoor /
outdoor PCB, indoor /
outdoor connection
wire
H12
Indoor unit capacity unmatched
90s after power
supply
—
• Total indoor
capability more than
maximum limit or less
than minimum limit,
or number of indoor
unit less than two
• Indoor / outdoor
connection wire,
indoor / outdoor PCB,
specification and
combination table in
catalogue
H14
Indoor intake air temperature sensor
abnormality
Continuous for 5s
—
• Indoor intake air
temperature sensor
open or short circuit
• Indoor intake air
temperature sensor
lead wire and
connector
H15
Compressor temperature sensor
abnormality
Continuous for 5s
—
• Compressor
temperature sensor
open or short circuit
• Compressor
temperature sensor
lead wire and
connector
H16
Outdoor current transformer (CT)
abnormality
—
—
• Current transformer
faulty or compressor
faulty
• Outdoor PCB faulty
or compressor faulty
H19
Indoor fan motor merchanism lock
Continuous
happen for 7 times
—
• Indoor fan motor lock
or feedback
abnormal
• Fan motor lead wire
and connector, fan
motor lock or block
H23
Indoor heat exchanger temperature
sensor abnormality
Continuous for 5s
—
• Indoor heat
exchanger
temperature sensor
open or short circuit
• Indoor heat
exchanger
temperature sensor
lead wire and
connector
H25
Indoor E-Ion abnormality
Port is ON for 10s
during E-Ion off
—
—
• E-Ion PCB
H27
Outdoor air temperature sensor
abnormality
Continuous for 5s
—
• Outdoor air
temperature sensor
open or short circuit
• Outdoor air
temperature sensor
lead wire and
connector
H28
Outdoor heat exchanger temperature
sensor 1 abnormality
Continuous for 5s
—
• Outdoor heat
exchanger
temperature sensor 1
open or short circuit
• Outdoor heat
exchanger
temperature sensor 1
lead wire and
connector
H30
Outdoor discharge pipe temperature
sensor abnormality
Continuous for 5s
—
• Outdoor discharge
pipe temperature
sensor open or short
circuit
• Outdoor discharge
pipe temperature
sensor lead wire and
connector
H32
Outdoor heat exchanger temperature
sensor 2 abnormality
Continuous for 5s
—
• Outdoor heat
exchanger
temperature sensor 2
open or short circuit
• Outdoor heat
exchanger
temperature sensor 2
lead wire and
connector
H33
Indoor / outdoor misconnection
abnormality
—
—
• Indoor and outdoor
rated voltage
different
• Indoor and outdoor
units check
H34
Outdoor heat sink temperature sensor
abnormality
Continuous for 2s
—
• Outdoor heat sink
temperature sensor
open or short circuit
• Outdoor heat sink
sensor
H36
Outdoor gas pipe temperature sensor
abnormality
Continuous for 5s Heating protection
operation only
• Outdoor gas pipe
temperature sensor
open or short circuit
• Outdoor gas pipe
temperature sensor
lead wire and
connector
Summary of Contents for CS-E24LKES
Page 9: ...9 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 10: ...10 5 Dimensions 5 1 Indoor Unit Remote Control ...
Page 11: ...11 5 2 Outdoor Unit ...
Page 12: ...12 6 Refrigeration Cycle Diagram ...
Page 13: ...13 7 Block Diagram ...
Page 14: ...14 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 15: ...15 8 2 Outdoor Unit 8 2 1 CU E24LKE ...
Page 16: ...16 8 2 2 CU E28LKE ...
Page 17: ...17 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 18: ...18 9 2 Outdoor Unit 9 2 1 CU E24LKE ...
Page 19: ...19 9 2 2 CU E28LKE ...
Page 20: ...20 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 23: ...23 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Page 24: ...24 10 2 2 Power Printed Circuit Board ...
Page 90: ...90 16 1 3 To remove power electronic controller ...
Page 91: ...91 16 1 4 To remove discharge grille 16 1 5 To remove control board ...
Page 92: ...92 16 1 6 To remove cross flow fan and indoor fan motor ...
Page 93: ...93 ...