7
1. Cooling capacities are based on indoor temperature of 27
°
C Dry Bulb (80.6
°
F Dry Bulb), 19.0
°
C Wet Bulb (66.2
°
F Wet Bulb)
and outdoor air temperature of 35
°
C Dry Bulb (95
°
F Dry Bulb), 24
°
C Wet Bulb (75.2
°
F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
°
C Dry Bulb (68
°
F Dry Bulb) and outdoor air temperature of 7
°
C Dry
Bulb (44.6
°
F Dry Bulb), 6
°
C Wet Bulb (42.8
°
F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20
°
C, outdoor 2/1
°
C.
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20
°
C, outdoor
-7/-8
°
C.
5. Specifications are subjected to change without prior notice for further improvement.
Thermostat
Electronic Control
Electronic Control
Protection Device
Electronic Control
Electronic Control
Dry Bulb
Wet Bulb
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
32
23
Minimum
16
11
16
11
Heating
Maximum
30
—
30
—
Minimum
16
—
16
—
Outdoor Operation Range
Cooling
Maximum
43
26
43
26
Minimum
16
11
16
11
Heating
Maximum
24
18
24
18
Minimum
-5
-6
-5
-6
MODEL
INDOOR
CS-E24LKES
CS-E28LKES
OUTDOOR
CU-E24LKE
CU-E28LKE
Summary of Contents for CS-E24LKES
Page 9: ...9 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 10: ...10 5 Dimensions 5 1 Indoor Unit Remote Control ...
Page 11: ...11 5 2 Outdoor Unit ...
Page 12: ...12 6 Refrigeration Cycle Diagram ...
Page 13: ...13 7 Block Diagram ...
Page 14: ...14 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 15: ...15 8 2 Outdoor Unit 8 2 1 CU E24LKE ...
Page 16: ...16 8 2 2 CU E28LKE ...
Page 17: ...17 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 18: ...18 9 2 Outdoor Unit 9 2 1 CU E24LKE ...
Page 19: ...19 9 2 2 CU E28LKE ...
Page 20: ...20 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 23: ...23 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Page 24: ...24 10 2 2 Power Printed Circuit Board ...
Page 90: ...90 16 1 3 To remove power electronic controller ...
Page 91: ...91 16 1 4 To remove discharge grille 16 1 5 To remove control board ...
Page 92: ...92 16 1 6 To remove cross flow fan and indoor fan motor ...
Page 93: ...93 ...