background image

7

English

FAN SPEED

To select fan speed

(Remote control display)

• For AUTO, the indoor fan speed is automatically 

adjusted according to the operation mode.

AIR SWING

To adjust vertical air

fl

 ow 

direction

AIR SWING

(Remote control display)

• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver 

swings up/down automatically.

• In HEAT mode, if AUTO is set, the horizontal 

louver is 

fi

 xed at the predetermined position.

• Do not adjust the louver by hand.

How to use

To set the timer

2 sets of ON and OFF timers are available 
to turn ON or OFF the unit at different preset 
times.

TIMER

SET

CANCEL

ON

OFF

1

2

3

AC

C

CANCEL

3

AC

C

2

1

3

1

Select ON or OFF 
timer

Example: 
OFF at 22:00

• Each time pressed:

OFF

Cancel

2

Set the time

2

3

Con

fi

 rm

SET

TIMER

• To cancel ON or OFF timer, press 

ON

 or 

OFF

 

to select respective   or   then press 

CANCEL

.

• If timer is cancelled manually or due to power 

failure, you can restore the timer again by 
pressing 

ON

 or 

OFF

 to select respective   or 

 then press 

SET

.

• The nearest timer setting will be displayed and 

will activate in sequence.

• When ON Timer is set, the unit may start 

earlier (up to 35 minutes) before the actual 
set time in order to achieve the desired 
temperature on time.

• Timer operation is based on the clock set in 

the remote control and repeats daily once set. 
For clock setting, please refer to Quick guide.

Auto Restart Control

• If power is resumed after a power failure, the 

operation will restart automatically after a period 
of time with previous operation mode and air

fl

 ow 

direction. 

• This control is not applicable when TIMER is set.

Summary of Contents for CS-E9SB4RW

Page 1: ... CS E9SB4RW Single Split Outdoor Unit CU E9SB4R Multi Split Outdoor Unit CU 2E18SBR CU 3E18SBR CU 4E23QBR CU 4E27QBR CU 5E32QBR Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference ...

Page 2: ...e for different indoor units The power indicator blinks to indicate the indoor unit is standing by for a different operation mode Outdoor unit Indoor units Operation conditions Use this air conditioner under the following temperature range DBT Dry bulb temperature WBT Wet bulb temperature Single split outdoor unit CU E9SB4R Indoor Outdoor DBT WBT DBT WBT COOL Max 32 23 46 26 Min 16 11 5 HEAT Max 3...

Page 3: ...UTO HEAT COOL 2 Start stop the operation POWER Please note that the indication is on display to start the unit 3 Select the desired temperature Selection range 16 C 30 C Operating the unit within the recommended temperature range may save energy HEAT 20 C 24 C COOL 26 C 28 C DRY 1 C 2 C lower than room temperature To dim or restore the unit s indicator brightness press and hold for 5 seconds Use r...

Page 4: ...Children should be supervised to ensure that they do not play with the appliance Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than ...

Page 5: ...nit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plants or pet directl...

Page 6: ...hile to warm up The POWER indicator blinks during this operation COOL To enjoy cool air To reduce power consumption during COOL mode use curtains to screen off sunlight and outdoor heat DRY To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation POWERFUL QUIET To switch between powerful quiet QUIET POWERFUL NORMAL POWERFUL To reach temperature quickly POWERF...

Page 7: ...ach time pressed OFF Cancel 2 Set the time 2 3 Confirm SET TIMER To cancel ON or OFF timer press ON or OFF to select respective or then press CANCEL If timer is cancelled manually or due to power failure you can restore the timer again by pressing ON or OFF to select respective or then press SET The nearest timer setting will be displayed and will activate in sequence When ON Timer is set the unit...

Page 8: ...O S E Remove Air Filter Knob Insert the air filter to the tabs of the intake grille Slowly bring up the intake grille Press the knobs to the CLOSE side Air Filter Installation 1 1 2 2 3 3 INDOOR UNIT Wipe the unit gently with a soft dry cloth AIR FILTER Vacuum wash and dry lt is recommended to clean the air filter every 6 weeks Do not operate without an air filter Wash rinse the air filter gently ...

Page 9: ...windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents Noisy during operation Check if the unit has been installed at an incline Close the intake grille properly Remote control does not work Display is dim or transmission signal is weak Insert the batteries correctly Replace weak batteries The unit does not work Check if the circuit breaker is tripped Chec...

Page 10: ...ols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved ...

Page 11: ...11 English Memo Information Memo ...

Page 12: ...ACXF55 03830 SZ0616 0 Printed in Malaysia Panasonic Corporation Website http www panasonic com Panasonic Corporation 2016 ...