background image

7

2.5.

CS-F24DB4E5 CU-J43DBE8

1. Cooling capacities are based on indoor temperature of 27

°

C D.B. (80.6

°

F D.B.), 19.0

°

C W.B. (66.2

°

F W.B.) and outdoor air

temperature of 35

°

C D.B. (95

°

F D.B.), 24

°

C W.B. (75.2

°

F W.B.)

2. Heating capacities are based on indoor temperature of 20

°

C D.B. (68

°

F D.B.) and outdoor air temperature of 7

°

C D.B. (44.6

°

F

D.B.), 6

°

C W.B. (42.8

°

F W.B.)

ELECTRICAL DATA (50 Hz)

ITEM / MODEL

 

Indoor Unit

Outdoor Unit

Main Body

CS-F24DB4E5 

×

 2

CU-J43DBE8

Panel

CZ-BT03P 

×

 2

Remote

Control

CZ-RD513C (Wired)

CZ-RL513B (Wireless)

Cooling Capacity

kW

12.5

BTU/h

42,600

Refrigerant Charge-less

m

30

Standard Air Volume for High, 

m

3

/min

18

94

cfm

636

3316

Outside Dimension (H x W x D)

mm

246 

×

 840 

×

 840

1170 

×

 900 

×

 320

inch

9-11/16 

×

 33-1/24 

×

 33-1/24

46-1/16 

×

 35-7/16 

×

 12-19/32

Net Weight

kg (lbs)

26 (58)

97 (214)

Piping
Connection

Refrigerant

Gas

mm (inch)

O.D Ø 15.88 (5/8) Flared Type

Liquid

mm (inch)

O.D Ø 9.52 (3/8) Flared Type

Drain

O.D Ø 20

I.D Ø 20

Compressor

Type, Number of Set

 

-

Hermetic, 1

Starting Method

 

-

Permanent Split Capacitor

Motor

Type

 

-

2-pole 3 phase brushless motor

Rated Output

kW

-

3.75

Fan

Type, Number of Set

 

Turbo fan-1

Mix flow fan,1

Motor

Type

 

8-pole DC motor

6-pole single phase induction motor

Rated Output

kW

0.04

0.07 

×

 2

Air-heat Exchanger (Row x Stage x FPI)

 

Louver-fin type (2 

×

 10 

×

 20)

Corrugate-fin type (2 

×

 44 

×

 20)

Refrigerant Control

 

-

Expansion Valve

Refrigerant Oil (Charged)

cm

3

-

DAPHNE FVC68D (1500)

Refrigerant (Charged) R410a

kg (oz)

-

3.10 (109)

Running 
Adjustment

Control Switch

 

Wireless or Wired Remote Control

-

Room Temperature

 

Thermostat

-

Noise Level

 dB (A)

Cooling:       36/32

56/-

Power Level 

dB

Cooling:       51/47

70/-

Moisture Removal

 L/h (Pt/h)

7.9 (16.6)

EER

 W/W

2.64/2.61/2.58

 ITEM / MODEL

Condition by ISO5151

Volts

V

380

400

415

Phase

 Three

Three

Three

Power Consumption

kW

Cooling

4.74

4.79

4.84

Running Current

A

Cooling

7.8

8.0

8.2

Starting Current

A

54

57

60

Power Factor

%

Cooling

92

86

82

*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic

Power source

AC, 3~380V,400V, 415V 50Hz

Summary of Contents for CS-F14DB4E5

Page 1: ...F14DB4E5 CU J28DBE5 3 2 2 CS F14DB4E5 CU J28DBE8 4 2 3 CS F18DB4E5 CU J34DBE5 5 2 4 CS F18DB4E5 CU J34DBE8 6 2 5 CS F24DB4E5 CU J43DBE8 7 2 6 CS F28DB4E5 CU J50DBE8 8 3 Twin Systems 9 3 1 Installation...

Page 2: ...ible Indoor units with same horsepowers can even be used in combination Master unit and slave units can be set automatically in twin systems No address setting is necessary Multiple indoor units can b...

Page 3: ...ype Drain mm O D 20 I D 20 Compressor Type Number of Set Hermetic 1 Starting Method Permanent Split Capacitor Motor Type 2 pole 1 phase brushless motor Rated Output kW 2 0 Fan Type Number of Set Turbo...

Page 4: ...O D 20 I D 20 Compressor Type Number of Set Hermetic 1 Starting Method Permanent Split Capacitor Motor Type 2 pole 3 phase brushless motor Rated Output kW 2 0 Fan Type Number of Set Turbo fan 1 Mix f...

Page 5: ...0 I D 20 Compressor Type Number of Set Hermetic 1 Starting Method Permanent Split Capacitor Motor Type 2 pole 1 phase brushless motor Rated Output kW 3 0 Fan Type Number of Set Turbo fan 1 Mix flow fa...

Page 6: ...20 I D 20 Compressor Type Number of Set Hermetic 1 Starting Method Permanent Split Capacitor Motor Type 2 pole 3 phase brushless motor Rated Output kW 3 0 Fan Type Number of Set Turbo fan 1 Mix flow...

Page 7: ...D 20 I D 20 Compressor Type Number of Set Hermetic 1 Starting Method Permanent Split Capacitor Motor Type 2 pole 3 phase brushless motor Rated Output kW 3 75 Fan Type Number of Set Turbo fan 1 Mix flo...

Page 8: ...D 20 I D 20 Compressor Type Number of Set Hermetic 1 Starting Method Permanent Split Capacitor Motor Type 2 pole 3 phase brushless motor Rated Output kW 4 5 Fan Type Number of Set Turbo fan 1 Mix flow...

Page 9: ...9 3 Twin Systems 3 1 Installation Manual...

Page 10: ...10...

Page 11: ...er is turned on while the transmission wires between the indoor units are not connected open circuit at section C Symptom Remote control unit check flashes Error code F30 01 connected indoor capacity...

Page 12: ...unit check flashes Error code F30 01 connected indoor capacity error Indoor unit LED1 on P C B flashes Outdoor unit LED6 7 on P C B flashes connected indoor capacity error Remedy 1 Turn off the main...

Reviews: