background image

F568406

Operating Instructions

Air Conditioner

 Model No.
 Indoor Unit 

Outdoor Unit 

 

 CS-KC9NKH-3 

CU-KC9NKH-3

 CS-KC12NKH-3 

CU-KC12NKH-3

QUICK GUIDE

QUICK GUIDE

ENGLISH  

Before operating the unit, read these operating 

instructions thoroughly and keep them for future 

reference.

© Panasonic Appliances Air-Conditioning Malaysia 
Sdn. Bhd. 2012. Unauthorized copying and distribution 
is a violation of law.

Summary of Contents for CS-KC9NKH-3

Page 1: ...CU KC9NKH 3 CS KC12NKH 3 CU KC12NKH 3 QUICK GUIDE QUICK GUIDE ENGLISH Before operating the unit read these operating instructions thoroughly and keep them for future reference Panasonic Appliances Air Conditioning Malaysia Sdn Bhd 2012 Unauthorized copying and distribution is a violation of law ...

Page 2: ...er or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product damage burst and injury etc Do not install the unit in a potentially explosive or ...

Page 3: ...ted following the polarity stated POWER SUPPLY Do not pull the cord to disconnect the plug to prevent electric shock WARNING WARNING REMOTE CONTROL Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries POWER SUPPLY Do not use a modified cord joint cord extension cord or unspecified cord to prevent overheating and fire To ...

Page 4: ...he room temperature Once auto mode is selected the unit will operate at the standard setting temperature Room temperature Operation mode Standard setting temperature 23 C above Cool 25 C Below 23 C Dry 22 C Press for HI to 2 C or for LO to 2 C to the standard setting temperature COOL mode To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool...

Page 5: ...mal High Low None Set Fan Speed Medium Fan 1 tap 2 C 1 C 1 C 1 tap COOL DRY Mode Set Temperature For first 15 minutes or until set temperature is reached The human activity sensor may not detect moving objects further than 7m away or beyond detection angle The human activity sensor sensitivity is influenced by indoor unit location movement speed temperature range etc The human activity sensor may ...

Page 6: ...by hand 8 AUTO OFF ON BUTTON Use when remote control is misplaced or a malfunction occurs Action Mode Press once Auto Press and hold until 1 beep is heard then release Cooling Press the button to turn off 9 ANTI BACTERIAL FILTER Anti bacterial filter Clean the filter whenever necessary Wash rinse the filter gently with water to avoid damage to the filter Dry the filter thoroughly under shade away ...

Page 7: ...icate malfunction SYMPTOM SYMPTOM CAUSE CAUSE Mist emerges from indoor unit Condensation effect due to cooling process Water flowing sound during operation Refrigerant flow inside the unit The room has a peculiar odor This may be due to damp smell emitted by the wall carpet furniture or clothing Indoor fan stops occasionally during automatic fan speed setting This helps to remove the surrounding o...

Page 8: ... Remote Control Preparation 1 2 3 TIMER SET CANCEL ON OFF 1 2 3 SET CLOCK RESET 4 5 6 1 Pull out 2 Insert AAA or R03 batteries can be used 1 year 3 Close the cover 4 Press CLOCK 5 Set time 6 Confirm QUICK GUIDE AIR SWING FAN SPEED MODE TEMP OFF ON TIMER SET CANCEL ON OFF 1 2 3 SET CLOCK RESET OFF TIMER ON TIMER FAN SPEED AIR SWING AUTO COOL DRY AUTO COMFORT ECONAVI 2 1 3 Printed in Malaysia F56840...

Reviews: