8
(1) Recommended dimensions of the baffle plates
D
E
C
J
H
K
G
B
I
P
Q
A
F
N
(2- 6.5 mm)
2- 1/4"
(2- 6 mm)
2- 15/64"
A
B
H
C
E
F
G
G
M
L
K
I
J
D
(4- 6.5 mm)
4- 1/4"
Fig. 5e
For Air Intake
For Air Discharge
Material to be used: Metal plate with corrosion protection treatment
Plate thickness:
0.0394 to 0.0472" (1.0 to 1.2 mm)
(2) Parts required (locally purchased except for screws)
Dimensions
A
B
C
D
E
F
G
H
I
J
K
N
P
Q
Model
CU-KS12NK1A
(inch) 21-21/32 25/32
2-5/32 17-5/16
13
25/64
19/32
23/64
19/64
17-3/8
25/64 5-29/32 25/32
25/32
(mm)
550
20
55
440
330
10
15
9
7.5
441
10
150
20
20
Dimensions
A
B
C
D
E
F
G
H
I
J
K
L
M
Model
CU-KS12NK1A
(inch) 19-3/32 20-3/32 13-25/32 5-29/32 17-17/32 25/32
2-5/32 14-9/16 2-3/4
3-11/32 19/32
1-3/8
1-3/8
(mm)
485
510
350
150
445
20
55
370
70
85
15
35
35
Air Intake Baffle
Air Discharge Baffle
Fig. 5d
Item
Q’ty
Remarks
Baffle plate
1
Screw 5/32
15/32" (4
12 mm) tapping
2
Attached to outdoor unit
Bolt 15/64
19/32 – 25/32" (M6
15 – 20 mm)
2
Nut 15/64" (M6)
2
Washer
2
Spring washer
2
Item
Q’ty Remarks
Baffle plate
1
Bolt 15/64
13/32 – 19/32" (M6
10 – 15 mm)
4
Nut 15/64" (M6)
4
Washer
4
Spring washer
4
Air Intake Baffle
Air Discharge Baffle
CU-KS12NK1A
Summary of Contents for CS-KS12NB41
Page 37: ...Outdoor Unit CU KS12NK1A 8FA2 5251 12300 2 37 ...
Page 69: ......
Page 117: ......
Page 118: ...Operating Instructions CZ RD515U 852 6 4181 230 00 1 APPENDIX C A 3 ...
Page 129: ......
Page 130: ...A 4 INSTALLATION INSTRUCTIONS CZ RD515U 852 6 4190 592 00 0 APPENDIX D ...
Page 135: ......
Page 136: ...DC1111 0 ...