background image

6

 Safety Precautions

Remote control

Do not use rechargeable (Ni-Cd) batteries. It 
may damage the remote control.

To prevent malfunction or damage of the 
remote control:
• Remove the batteries if the unit is not going 

to be used for a long period of time.

• New batteries of the same type must be 

inserted following the polarity stated.

Power supply

Do not disconnect the plug by pulling the cord 
to prevent electric shock.

WARNING

This appliance is 

fi

 lled with R32 

(mild 

fl

 ammable refrigerant)

If the refrigerant is leaked and exposed 
to an external ignition source, there is a 
risk of fi re.

Indoor unit and outdoor unit

The appliance shall be installed, and/or 
operated in a room with fl oor area larger 
than 

A

min

 (m²) and keep away from ignition 

sources, such as heat/sparks/open fl ame or 
hazardous areas such as gas appliances, gas 
cooking, reticulated gas supply systems or 
electric cooking appliances, etc. (Refer to Table 
A of Installation instructions table for 

A

min

 (m²))

Be aware that refrigerant may not contain an 
odour, highly recommended to ensure suitable 
fl ammable refrigerant gas detectors are 
present, operating and able to warn of a leak.
Keep any required ventilation openings clear of 
obstruction.
Do not pierce or burn as the appliance is 
pressurized. Do not expose the appliance 
to heat, fl ame, sparks, or other sources of 
ignition. Else it may explode and cause injury 
or death.

Precaution for using R32 refrigerant

The basic installation work procedures are the same as 
conventional refrigerant (R410A, R22) models.

Since the working pressure is higher than that 
of refrigerant R22 models, some of the piping 
and installation and service tools are special. 
Especially, when replacing a refrigerant R22 
model with a new refrigerant R32 model, 
always replace the conventional piping and 
fl are nuts with the R32 and R410A piping and 
fl are nuts on the outdoor unit side. 
For R32 and R410A, the same fl are nut on the 
outdoor unit side and pipe can be used.
The mixing of diff erent refrigerants within 
a system is prohibited. Models that use 
refrigerant R32 and R410A have a diff erent 
charging port thread diameter to prevent 
erroneous charging with refrigerant R22 and 
for safety. 
Therefore, check beforehand. [The charging 
port thread diameter for R32 and R410A is 1/2 
inch.]
Must always ensure that foreign matter (oil, 
water, etc.) does not enter the piping. Also, 
when storing the piping, securely seal the 
opening by pinching, taping, etc. (Handling of 
R32 is similar to R410A.)
• Operation, maintenance, repairing and 

refrigerant recovery should be carried 
out by trained and certifi ed personnel in 
the use of fl ammable refrigerants and as 
recommended by the manufacturer. Any 
personnel conducting an operation, servicing 
or maintenance on a system or associated 
parts of the equipment should be trained and 
certifi ed.

• Any part of refrigerating circuit (evaporators, 

air coolers, AHU, condensers or liquid 
receivers) or piping should not be located in 
the proximity of heat sources, open fl ames, 
operating gas appliance or an operating 
electric heater.

• The user/owner or their authorised 

representative shall regularly check the 
alarms, mechanical ventilation and detectors, 
at least once a year, where as required by 
national regulations, to ensure their correct 
functioning.

Summary of Contents for CS-MZ16ZKE

Page 1: ...ZKE CU Z50ZKE CS XZ20ZKEW H CS XZ25ZKEW H CS XZ35ZKEW H CS XZ42ZKEW H CU Z20ZKE CU Z25ZKE CU Z35ZKE CU Z42ZKE Multi Split CU 2Z35TBE CU 2Z41TBE CU 2Z50TBE CU 3Z52TBE CU 3Z68TBE CU 4Z68TBE CU 4Z80TBE C...

Page 2: ...e Split System or Multi Split System Air Conditioner to suit your needs For complete product features please refer to catalogue Inserting the batteries 1 2 3 1 Pull out the back cover of remote contro...

Page 3: ...control display 3 Press TEMP UP TEMP DOWN to select the desired temperature Up Down Selection range 16 0 C 30 0 C 60 F 86 F Press for approximately 10 seconds to show the temperature as C or F 2 Pres...

Page 4: ...cialist to clean the internal parts repair install remove disassemble and reinstall the unit Improper installation and handling will cause leakage electric shock or re Con rm with authorised dealer or...

Page 5: ...cal shock or re Prevent electric shock by switching o the power supply and unplug Before cleaning or servicing When extended non use or During abnormally strong lightning activity CAUTION Indoor unit...

Page 6: ...he working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrige...

Page 7: ...ironmental e ects such as the danger of water collecting and freezing in relief pipes or the accumulation of dirt and debris h Expansion and contraction of long runs piping in refrigerating systems sh...

Page 8: ...ignition and hot metal surfaces away 2 3 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is a...

Page 9: ...e refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks t...

Page 10: ...nt in the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental e ects The check shall a...

Page 11: ...pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any potential ignition sources and there is ventilation available OFN oxygen free nitrogen type of inert gas 9 Ch...

Page 12: ...ardous condition when charging or discharging the refrigerant To avoid re or explosion dissipate static electricity during transfer by grounding and bonding containers and equipment before charging di...

Page 13: ...acuated to an acceptable level to make certain that ammable refrigerant does not remain within the lubricant The evacuation process shall be carried out prior to returning the compressor to the suppli...

Page 14: ...ow the remote control setting If nanoe X is activated before the unit is turned o the nanoe X operation will resume when the unit is turned on This includes when TIMER ON is set Press the button again...

Page 15: ...time This operation provides you with a comfortable environment while sleeping It will automatically adjust the sleep pattern temperature during the activation period The indoor unit indicator will di...

Page 16: ...ion This control is not applicable when TIMER is set To Learn More Single Single split system Multi Multi split system Operation mode It is possible to operate the indoor units individually or simulta...

Page 17: ...Z50ZKE CU Z71ZKE 2 CU 2Z35TBE CU 2Z41TBE CU 2Z50TBE CU 3Z52TBE CU 3Z68TBE CU 4Z68TBE CU 4Z80TBE CU 5Z90TBE Inside Cleaning This function is to enhance the inside cleaning of the air conditioner indoo...

Page 18: ...ugh items e g ngernails tools rings etc Wipe the unit gently with a soft damp cloth The coils and fans should be cleaned periodically by an authorised dealer Outdoor unit Clean the debris that surroun...

Page 19: ...hen room temperature increase Indoor fan stops occasionally during heating operation To avoid unintended cooling e ect Indoor fan stops occasionally during automatic fan speed setting This is to help...

Page 20: ...ly Remote control does not work Display is dim or transmission signal is weak Insert the batteries correctly Replace weak batteries The unit does not work Check if the circuit breaker is tripped Check...

Page 21: ...the air inlets and outlet vents Use AUTO OFF ON on the unit to select COOL or HEAT mode For details refer The remote control is missing or a malfunction has occurred above After 15 minutes of operatio...

Page 22: ...35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mismatch brand cod...

Page 23: ...y or dealer and ask for the correct method of disposal Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies w...

Page 24: ...a branch of Panasonic Marketing Europe GmbH Maxis 2 Western Road Bracknell Berkshire RG12 1RT Manufactured by Panasonic Corporation 1006 Oaza Kadoma Kadoma City Osaka 571 8501 Japan Importer Panasonic...