46
12.13 +8/10°C Heat Operation
•
+8/10°C Heat operation provides heating at low setting temperature in unoccupied houses during winter for the
purpose of protecting equipments or housing appliances which may be destroyed by the extreme cold weather.
•
This operation can be ON by pressing the +8/10°C heat button on the remote control.
•
Two temperature settings are available, which are;
o
8°C (Pressing TEMP down button at the remote control)
o
10°C (Pressing TEMP up button at the remote control)
•
During the operation of this mode;
o
The indoor fan speed will remain at Hi fan tap all the time included deice process.
o
Powerful operation, Quiet operation, Econavi operation and Fan Speed selection are disabled.
o
Cold draft prevention control is disabled.
•
Control
condition;
•
Caution!
If the indoor temperature constantly is less than 0°C (Door, windows not close properly), the error code F11 may
occur. This is because in open area, the indoor sensor will misjudge operation condition and will give error code.
Summary of Contents for CS-NE9NKE
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit...
Page 14: ...14 5 2 Outdoor Unit...
Page 15: ...15 6 Refrigeration Cycle Diagram...
Page 16: ...16 7 Block Diagram...
Page 17: ...17 8 Wiring Connection Diagram 8 1 Indoor Unit...
Page 19: ...19 9 Electronic Circuit Diagram 9 1 Indoor Unit...
Page 20: ...20 9 2 Outdoor Unit...
Page 23: ...23 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board...
Page 29: ...29...
Page 90: ...90 Figure 3 Figure 4 16 1 1 3 To remove discharge grille Figure 5...
Page 92: ...92 Figure 8 Figure 9...
Page 93: ...93 Figure 10...