background image

30

AIR CONDITIONER

ON

OFF

SET

TIMER

CANCEL

OFF/ON

AIR SWING

TEMP

OFF/ON

MODE

SLEEP

FAN SPEED/

QUIET

POWERFUL/

ECO

How to use

Upper direction: 

• Do not adjust the 

fl

 ap by hand.

Lateral direction: 

• For lateral direction, it is 

manually adjustable as shown.

To adjust air

fl

 ow direction 

AIR SWING

Upper direction

Not used 

in normal 

operations.

Press to restore 

the remote 

control to default 

setting.

• nanoe™-G starts automatically when the unit is turned on 

with 

OFF/ON

OFF/ON

.

• This operation can be turned ON or OFF manually by 

pressing 

.

• This operation can be activated even when the unit is 

turned off. In this condition, the 

fl

 ap and fan speed will 

operate based on remote control setting.

• If power failure occurs during this operation, this operation 

will be resumes immediately after power resumes.

To enjoy freshness and cleaner environment

nanoe-G

Indicator

POWER

 

TIMER

  

nanoe-G

 

ECO

 

To adjust FAN SPEED and QUIET condition

FAN SPEED: 

• For AUTO, the indoor fan speed is automatically adjusted 

according to the operation mode.

QUIET: 

• This operation reduces air

fl

 ow noise.

POWERFUL: 
To reach set temperature quickly

• This operation stops automatically after 4 hours.

ECO: 

• To reduce power consumption for better energy saving 

without sacri

fi

 cing comfort.

FAN SPEED/

QUIET

To switch between POWERFUL/ECO

POWERFUL/

ECO

Lateral
direction

(exit setting)

Summary of Contents for CS-PU9WKH-8M

Page 1: ...hi l p t Operating Instructions Air Conditioner 20 37 Before operating the unit please read these operating instructions thoroughly and keep them for future reference The included Installation Instruc...

Page 2: ...2 3 1 1 K o n p y l ng c a i u khi n 2 L p pin AAA ho c R03 3 y n p A i u ch nh ng h 1 Nh n v t th i gian Nh n v gi n t trong kho ng 5 gi y hi n th th i gian theo 12 gi am pm ho c 24 gi 2 X c nh n SE...

Page 3: ...i i th ch v c th kh c so v i m y th c Nh s n xu t c th thay i m kh ng b o tr c nh m m c ch c i ti n s n ph m C m n b n l a ch n M y i u h a kh ng kh Panasonic B C c t nh n ng c b n 2 Nh n MODE ch n ch...

Page 4: ...n ng ch u tr ch nhi m v an to n cho h Kh ng n n tr em ngh ch ch i v i m y Vui l ng li n h v i i l y quy n ho c chuy n gia v sinh c c b ph n b n trong s a ch a l p t th o v l p l i m y L p t v x l kh n...

Page 5: ...ng i u khi n t xa Th o pin kh i i u khi n t xa n u kh ng s d ng trong th i gian d i Pin m i c ng lo i ph i c l p ng c c nh ch d n Ngu n c p i n Kh ng k o d y ngu n ra kh i c m tr nh b gi t i n Ngu n...

Page 6: ...c n b c k n u h b ng k p d y bu c b o qu n R32 gi ng nh b o qu n R410A Vi c v n h nh b o d ng s a ch a v n p l i m i ch t l m l nh ph i c ti n h nh b i c c nh n vi n c o t o v ch ng nh n v ph i c gi...

Page 7: ...x l theo ng quy nh 2 B o tr 2 1 Nh n vi n b o tr H th ng c ki m tra th ng xuy n gi m s t v s a ch a b i nh n vi n b o h nh c o t o v ch ng nh n c thu b i ng i s d ng hay m t t ch c c tr ch nhi m C n...

Page 8: ...g gi ph i m b o ph n t n m i ch t l m l nh c th i ra m t c ch an to n v t t h n l n n th i ra ngo i kh ng kh 2 7 Ki m tra thi t b l m l nh Khi ph i thay i c c thi t b i n ph i s d ng c c thi t b m i p...

Page 9: ...m n c ph i ch u p l c ph c b rung c c c m p s c hay ch u c c t c ng kh c c a m i tr ng hay kh ng Vi c ki m tra c ng c n t nh n nh h ng c a th i gian s d ng c a thi t b hay s rung li n t c t c c ngu n...

Page 10: ...ch h p theo h ng d n m b o r ng h th ng l m l nh c ti p t tr c khi n p m i ch t l m l nh cho h th ng D n nh n l n h th ng khi qu tr nh n p li u ho n t t n u ch a c l m C n ph i h t s c c n tr ng kh n...

Page 11: ...qu tr nh n p m i ch t cho to n h th ng M i b nh ch a c s d ng ph i c quy nh r cho c c m i ch t c thu h i v ph i c d n nh n c n th n cho m i ch t c ngh a l c c b nh ch a c bi t thu h i m i ch t B nh c...

Page 12: ...n y c th c B T ho c T T th c ng b ng c ch nh n Ch n y c th c k ch ho t khi m y t t Trong tr ng h p n y t c c a c nh o gi v qu t s ho t ng theo c i t c a i u khi n t xa N u m t i n khi m y ang ch y ch...

Page 13: ...NCEL CANCEL 1 2 3 1 Ch n ch h n gi ON B T hay OFF T T m y V d OFF T T l c 22 00 gi M i l n b m OFF 7KL W O S FK WKRiW 2 Ch n th i gian 3 X c nh n SET h y ch h n gi n ON ho c OFF ch n thi t l p ho c r...

Page 14: ...M L NH 26 0 C 28 0 C 79 F 82 F H ng gi ch COOL DRY L M L NH H T M N u thi t l p AUTO T NG c nh o gi s t ng di chuy n l n xu ng i u khi n ch t kh i ng N u i n c kh i ph c sau khi m t i n c c qu tr nh...

Page 15: ...Kh ng ch m v o trong khi m y ang ho t ng L i l c kh 2 tu n m t l n R a tr ng l i l c nh nh ng tr nh l m h b m t l i l c Ph i kh l i l c trong b ng r m tr nh xa l a ho c ph i tr c ti p d i n ng Thay l...

Page 16: ...c c linh ki n b ng nh a s b b c m u nhanh h n khi ti p x c v i nhi t nh s ng m t tr i tia c c t m ho c y u t m i tr ng B i c th b m v o xung quanh b ng i u khi n ph a tr c l i t n nhi t v t ng bao qu...

Page 17: ...ph t ho t ng n u ch nh l ch nhi t gi a c a gi v o v c a gi ra nh d i y c ngh a l m y ho t ng b nh th ng COOL L M L NH 8 C 14 4 F M y s kh ng c s d ng trong m t th i gian d i B t ch nanoeTM G trong 2...

Page 18: ...1 C m bi n h b i c v n H 32 C m bi n nhi t d n trao i nhi t s 2 c a kh i ngo i b t th ng H 33 Kh i trong kh i ngo i m t k t n i v i nhau H 34 C m bi n nhi t b l m m t kh i ngo i b t th ng H 35 N c ng...

Page 19: ...ng nhau K hi u n y c th d ng k t h p v i m t k hi u h a h c Trong tr ng h p n y n tu n th c c quy nh c li n quan v h a ch t B O NG Bi u t ng n y cho bi t thi t b d ng m i ch t l m l nh c th g y ch y...

Page 20: ...back cover of remote control 2 Insert AAA or R03 batteries 3 Close the cover A Clock setting 1 Press and set the time Press and hold for approximately 5 seconds to show time in 12 hour am pm or 24 hou...

Page 21: ...y differ from the actual unit They are subject to change without notice for future improvement B Basic operation 2 Press MODE to select the desired mode DRY AUTO COOL 1 Press OFF ON OFF ON to start st...

Page 22: ...e supervised to ensure that they do not play with the appliance Please consult an authorised dealer or specialist to clean the internal parts repair install remove disassemble and reinstall the unit I...

Page 23: ...long period of time New batteries of the same type must be inserted following the polarity stated Power supply Do not disconnect the plug by pulling the cord to prevent electric shock nanoe G generat...

Page 24: ...al the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use o...

Page 25: ...the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised...

Page 26: ...ternally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the...

Page 27: ...the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also...

Page 28: ...minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging...

Page 29: ...employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refri...

Page 30: ...when the unit is turned off In this condition the flap and fan speed will operate based on remote control setting If power failure occurs during this operation this operation will be resumes immediate...

Page 31: ...IET POWERFUL ECO Can be selected at the same time Can be activated in all modes Can be cancelled by pressing the respective button again POWERFUL QUIET and FAN SPEED cannot be selected at the same tim...

Page 32: ...nergy COOL 26 0 C 28 0 C 79 F 82 F Air flow direction In COOL DRY mode If AUTO is set the flaps swings up down automatically Auto restart control If power is resumed after a power failure the operatio...

Page 33: ...n Air filters Once every 2 weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under shade away from fire or direct sunlight Replace any dam...

Page 34: ...iscoloration is subject to material types used in plastic parts accelerated when exposed to heat sun light UV light or environmental factor Dust may have collected around the front panel grilles and w...

Page 35: ...tion After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F The units are not going to be used for a long period...

Page 36: ...heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnorma...

Page 37: ...ght be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved WARNING This symbol shows that this equipment uses a flam...

Page 38: ...Memo...

Page 39: ...Memo...

Page 40: ...Printed in Malaysia ACXF55 26883 SA0220 3 Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan Website http www panasonic com Panasonic Corporation 2020...