12.3.5 Automatic Restart Control
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to
four minutes after power supply resumes.
12.3.6 Indication
Panel
LED POWER
TIMER
Color Green
Orange
Light ON
Operation ON
Timer setting ON
Light OFF
Operation OFF
Timer setting OFF
Note:
ϥ
If POWER LED blinks, the possible operation of the unit is operation mode judgment, or ON timer
sampling.
ϥ
If Timer LED blinks, there is an abnormal operation occurs.
12.3.7 Timer
control
Delay ON Timer ca be set using remote controller, the unit with timer set will start operate earlier than the setting time.
This is to provide a comfortable environment when reaching the set On time. Seventy minutes before the set time for
ON Timer or ON-OFF Timer setting, indoor ( at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds
to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation mode.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
Timer Signal Receiving sound During Operation.
Timer Signal Receiving Sound When the Air Conditioner Stops.
35
Summary of Contents for CS-RE9JKE
Page 14: ...14 5 2 Outdoor Unit Unit mm...
Page 15: ...15 6 Refrigeration Cycle Diagram CS CU RE9JKE CS CU RE12JKE CS CU RE15JKE COOLING HEATING...
Page 16: ...16 7 Block Diagram CS CU RE15JKE CS CU RE9 12JKE...
Page 17: ...17 8 Wiring Diagram 6 8 5 6 8 5...
Page 18: ...18 6 8 5...
Page 19: ...19 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board TOP VIEW...
Page 20: ...20 BOTTOM VIEW...
Page 21: ...21 9 1 2 Indicator receiver TOP VIEW BOTTOM VIEW...
Page 22: ...22 9 2 Outdoor Unit 9 2 1 CU RE9JKE CU RE12JKE TOP VIEW BOTTOM VIEW...
Page 25: ...25 10 2 3 Indoor Unit Installation...
Page 42: ...42 14 2 3 Error Codes Table...
Page 46: ...46 16 Exploded View and Replacement Pars List 16 1 Indoor Unit CS RE9JKE CS RE12JKE CS RE15JKE...
Page 48: ...48 16 2 Outdoor Unit CU RE9JKE CU RE12JKE...
Page 50: ...50 CU RE15JKE...