4
CAUTION
17. After completion of installation, confirm there is no leakage of refrigerant gas. It may generate toxic gas when the
refrigerant contacts with fire.
18. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when the refrigerant contacts with
fire.
19. Recommended installation height for indoor unit shall be at least 2.5 m.
20. The appliance shall be installed in accordance with national wiring regulations.
21. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing.
22. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.
1. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at
surrounding of the unit, it may cause fire.
2. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room
and damage the furniture.
3. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long
period, the flare may break and cause refrigerant gas leakage.
4. Do not touch outdoor unit air inlet and aluminums fin. It may cause injury.
5. Select an installation location which is easy for maintenance.
6. Power supply connection to the air conditioner.
Connect the power supply cord of the air conditioner to the mains using one of the following methods.
Power supply point should be in easily accessible place for power disconnection in case of emergency.
In some countries, permanent connection of this air conditioner to the power supply is prohibited.
1) Power supply connection to the receptacle using a power plug.
Use an approved 15/16A power plug with earth pin for the connection to the receptacle.
2) Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for
the permanent connection. It must be a double pole switch with a minimum 3.5 mm contact gap.
7. Do not release refrigerant.
Do not release refrigerant during piping work for installation, re-installation and during repairing a refrigeration parts.
Take care of the liquid refrigerant, it may cause frostbite.
8. Installation work.
It may need two people to carry out the installation work.
9. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
10. Do not sit ot step on the unit, you may fall down accidentally.
11. Do not touch the sharp aluminium fin, sharp parts may cause injury.
12. Thermal fuse specification for indoor unit: 250V 3.15A T3.15AL; outdoor unit: 205V 3.15A T3.15AL,205V 20A T20AL.
Summary of Contents for CS-RE9JKE
Page 14: ...14 5 2 Outdoor Unit Unit mm...
Page 15: ...15 6 Refrigeration Cycle Diagram CS CU RE9JKE CS CU RE12JKE CS CU RE15JKE COOLING HEATING...
Page 16: ...16 7 Block Diagram CS CU RE15JKE CS CU RE9 12JKE...
Page 17: ...17 8 Wiring Diagram 6 8 5 6 8 5...
Page 18: ...18 6 8 5...
Page 19: ...19 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board TOP VIEW...
Page 20: ...20 BOTTOM VIEW...
Page 21: ...21 9 1 2 Indicator receiver TOP VIEW BOTTOM VIEW...
Page 22: ...22 9 2 Outdoor Unit 9 2 1 CU RE9JKE CU RE12JKE TOP VIEW BOTTOM VIEW...
Page 25: ...25 10 2 3 Indoor Unit Installation...
Page 42: ...42 14 2 3 Error Codes Table...
Page 46: ...46 16 Exploded View and Replacement Pars List 16 1 Indoor Unit CS RE9JKE CS RE12JKE CS RE15JKE...
Page 48: ...48 16 2 Outdoor Unit CU RE9JKE CU RE12JKE...
Page 50: ...50 CU RE15JKE...