background image

8

 
 

Indoor Unit
Outdoor Unit

Test conditions
1.  Cooling: Indoor Dry Bulb Temp. (°C) 27  

Outdoor  Dry Bulb Temp. (°C) 35

 

  Wet Bulb Temp. (°C) 19  

 

Wet  Bulb Temp. (°C) 24

Heating: Indoor Dry Bulb Temp. (°C) 20  

Outdoor  Dry Bulb Temp. (°C) 7

 

  Wet Bulb Temp. (°C) 12 (MAX)   

Wet Bulb Temp. (°C) 6

2. Standard piping length: 7.5m (Includes Indoor Unit piping length).

 

 

 Model

 
 

 CS-RE9JKR

         CU-RE9JKR

 
 

 CS-RE12JKR

         CU-RE12JKR

COOL HEAT COOL HEAT COOL HEAT COOL HEAT

Single, 230V, 

50Hz

Single, 240V, 

50Hz

Single, 230V, 

50Hz

Single, 240V, 

50Hz

 

 Power/Current

[kW]

0.700 0.820 0.700 0.820 1.010 1.120 1.010 1.120

[A]

3.30

3.80

3.20

3.70

4.80

5.20

4.70

5.10

 

  Refrigerant

[k

g

]

R410A

0.810

R410A

0.970

  Cooling Capacity

[kW]

2.500

3.500

 

 Heating Capacity

[kW]

3.300

4.250

Noise Level

JIS C 9612 [<70 
dB(A)]

[dB(A)]

   

42

42

42

42

Conditions 1m 
Distance Max. 
cooling/heating 
operation

47

48

47

48

48

50

48

50

Sound power 
level

[dB(A)]

   

53

53

53

53

60

61

60

61

61

63

61

63

 

 Air Circulation

[m

3

/min.]

13.8

13.8

13.8

13.8

13.8

14.5

13.8

14.5

 

k

g

 Product Weight

[k

g

]

   

8.5

8.5

26

28.5

 

 Dimensions (L x W x H)

[mm]

   

848 × 204 × 290

848 × 204 × 290

780 × 289 × 540

780 × 289 × 540

  

PRODUCT SPECIFICATION

 PRODUCT SPECIFICATION

F566894_EN1.indd   章节2:8

F566894_EN1.indd   章节2:8

2009-6-5   11:01:42

2009-6-5   11:01:42

Summary of Contents for CS-RE9JKR

Page 1: ...ic Home Appliances Air Conditioning Guangzhou Co Ltd 2008 Unauthorized copying and distribution is a violation of law QUICK GUIDE QUICK GUIDE ENGLISH 2 7 Before operating the unit read these operating...

Page 2: ...er objects into the unit rotating parts may cause injury Do not attempt to repair the unit by yourself Power Supply Do not pull the cord to disconnect the plug Switch off the power supply and unplug b...

Page 3: ...TION 8 QUICK GUIDE BACK COVER Do not switch ON the unit when waxing the floor After waxing aerate the room properly before operating the unit Do not install the unit in oily and smoky areas Replacemen...

Page 4: ...ly TO SET TEMPERATURE Selection range 16 C 30 C Operating the unit within the recommended temperature could induce energy saving HEAT mode 20 C 24 C COOL mode 26 C 28 C DRY mode 1 C 2 C lower than roo...

Page 5: ...s the button to select the delay hour The ON TIMER can only be set while the air conditioner is not in operation DELAYOFFAND ON TIMER For example to stop the air conditioner 3 hours later and start 4...

Page 6: ...r outlet vents Cooling 8 C Heating 14 C NON SERVICEABLE CRITERIAS NON SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY AND UNPLUG then CALL Authorized Distributor under the following conditions Abnormal no...

Page 7: ...Auto Restart function of the unit Operation will be restarted automatically under the previous operation mode and airflow direction when power is resumed as the operation is not stopped by remote cont...

Page 8: ...nt kW 0 700 0 820 0 700 0 820 1 010 1 120 1 010 1 120 A 3 30 3 80 3 20 3 70 4 80 5 20 4 70 5 10 Refrigerant kg R410A 0 810 R410A 0 970 Cooling Capacity kW 2 500 3 500 Heating Capacity kW 3 300 4 250 N...

Page 9: ...MEMO MEMO F566894_EN1 indd 2 9 F566894_EN1 indd 2 9 2009 6 15 10 32 16 2009 6 15 10 32 16...

Page 10: ...OFF ON ON OFF AUTO HEAT COOL DRY A B FAN SPEED SWING AIR AUTO AUTO POWERFUL POWERFUL POWERFUL QUIET POWERFUL QUIET AUTOQUIET AUTOQUIET OFF Remote Control Preparation Remote Control Preparation F566894...

Reviews: