8
Indoor Unit
Outdoor Unit
Test conditions
1. Cooling: Indoor Dry Bulb Temp. (°C) 27
Outdoor Dry Bulb Temp. (°C) 35
Wet Bulb Temp. (°C) 19
Wet Bulb Temp. (°C) 24
Heating: Indoor Dry Bulb Temp. (°C) 20
Outdoor Dry Bulb Temp. (°C) 7
Wet Bulb Temp. (°C) 12 (MAX)
Wet Bulb Temp. (°C) 6
2. Standard piping length: 7.5m (Includes Indoor Unit piping length).
Model
CS-RE9JKR
CU-RE9JKR
CS-RE12JKR
CU-RE12JKR
COOL HEAT COOL HEAT COOL HEAT COOL HEAT
Single, 230V,
50Hz
Single, 240V,
50Hz
Single, 230V,
50Hz
Single, 240V,
50Hz
Power/Current
[kW]
0.700 0.820 0.700 0.820 1.010 1.120 1.010 1.120
[A]
3.30
3.80
3.20
3.70
4.80
5.20
4.70
5.10
Refrigerant
[k
g
]
R410A
0.810
R410A
0.970
Cooling Capacity
[kW]
2.500
3.500
Heating Capacity
[kW]
3.300
4.250
Noise Level
JIS C 9612 [<70
dB(A)]
[dB(A)]
42
42
42
42
Conditions 1m
Distance Max.
cooling/heating
operation
47
48
47
48
48
50
48
50
Sound power
level
[dB(A)]
53
53
53
53
60
61
60
61
61
63
61
63
Air Circulation
[m
3
/min.]
13.8
13.8
13.8
13.8
13.8
14.5
13.8
14.5
k
g
Product Weight
[k
g
]
8.5
8.5
26
28.5
Dimensions (L x W x H)
[mm]
848 × 204 × 290
848 × 204 × 290
780 × 289 × 540
780 × 289 × 540
PRODUCT SPECIFICATION
PRODUCT SPECIFICATION
F566894_EN1.indd 章节2:8
F566894_EN1.indd 章节2:8
2009-6-5 11:01:42