Multi Zone Submittal Data
Indoor:
CS-S9NKUW-1
Wall Mounted Air Conditioner's
Job Name:
Approval:
Location:
Date:
Engineer:
Construction:
Submitted to:
Unit #:
Submitted by:
Drawing #:
Reference:
Power
V/PH/Hz
230/208/1/60
Refrigerant
Circuit Ampacity
(A)
15
Control
Electric Expansion Valve
Fuse Size, Max.
(A)
15
Connection
Line Size
(in. O.D. Discharge)
1/4"
Indoor Unit
Line Size
(in. O.D. Suction)
3/8"
Fan type
Cross Flow
No. Speeds
5
Dimensions
(in.)
Height
Width
Depth
RPM
(High)
Indoor Unit
(Uncrated)
11-7/16"
34-9/32"
8-1/16"
Motor Output
(W)
40
CFM
(QLo/Lo/Me/Hi/SHi)
199/239/321/400/442
Weight
Indoor
Indoor Sound Rating
(Hi) (dB-A)
40
Net
(lbs.)
20
Coil Type
Aluminum Fin & Copper Tube
Shipping
(lbs.)
Fin Type - Pipe Type
Slit Plate - Inner Rifled
Rows - F.P.I
2-19
Face Area
(sq.ft)
Cooling
Drain Connection Size
(in.)
5/8"
Total Capacity
(BTU/H)
SEER
17.5
Features
Dehumidification
(Pints/H)
1.3
Wireless Remote Controller Standard
Wired Remote Controller ( CZ-RD516C ) Optional
Operating Range
Controls
Microprocessor
Indoor Air Intake Temp.
Remote Controller
LCD Wireless Type, Temp, Sensor Built In
Cooling
Maximum
90F DB/74F WB
Temperature Control
IC Thermostat
Minimum
60F DB/52F WB
Air Louver
(Horizontal)
Manual
(Vertical)
Automatic
Power Failure Automatic Restart
Built-In
Self-Diagnosis
Built-In
Air Filter
Washable, Anti-Mold
R410A
Flare
10200
Performance Data @ ARI Standard Conditions (230/208V)