65
•
Human activity judgment is as following
Signal Detection
Information Log
Area of Living Classification Judgment
Human Position Analysis
Target Area & Position Judgment
Human Activity Level Judgment
Setting Position Judgment
11.13.1.1 Signal
Detection
7m
120º
A
B
C
2m
7m
•
Human Activity sensor will turns on according to infrared sensors signal detection.
Signal detection
Human Activity Indicator
Sensor 1
Sensor 2
Possible detected human
position area
Left Center Right
1 0
C
■
■
□
0 1
A
□
■
■
B
■
□
■
A & C
■
□
■
B & C
■
□
■
A & C
■
□
■
1 1
A, B & C
■
□
■
0 0
-
■
■
■
*
□
Indicator ON,
■
Indicator OFF
•
However, once the Human Activity Indicator is ON, it will maintain ON status for 5 seconds. If there is no signal
detection from either infrared sensor, the final display condition will be kept until absence status.
11.13.1.2 Information
Log
•
The signal from Infrared sensors will be log to human activity database for further analysis.
Summary of Contents for CS-S9NKV
Page 15: ...15 4 2 3 CU S18NKV CU S24NKV...
Page 16: ...16 4 2 4 CU S28NKV...
Page 17: ...17 5 Refrigeration Cycle Diagram 5 1 CS S9NKV CU S9NKV CS S12NKV CU S12NKV...
Page 18: ...18 5 2 CS S18NKV CU S18NKV CS S24NKV CU S24NKV...
Page 19: ...19 5 3 CS S28NKV CU S28NKV...
Page 24: ...24 7 Wiring Connection Diagram 7 1 Indoor Unit 7 1 1 CS S9NKV CS S12NKV...
Page 25: ...25 7 1 2 CS S18NKV CS S24NKV...
Page 26: ...26 7 1 3 CS S28NKV...
Page 31: ...31 8 Electronic Circuit Diagram 8 1 Indoor Unit 8 1 1 CS S9NKV CS S12NKV...
Page 32: ...32 8 1 2 CS S18NKV CS S24NKV...
Page 33: ...33 8 1 3 CS S28NKV...
Page 41: ...41 9 1 5 Human Activity Sensor Printed Circuit Board...
Page 42: ...42 9 2 Outdoor Unit 9 2 1 Main Printed Circuit Board 9 2 1 1 CU S9NK...
Page 43: ...43 9 2 1 2 CU S12NK...
Page 44: ...44 9 2 1 3 CU S18NK CU S24NK...
Page 45: ...45 9 2 1 4 CU S28NK...
Page 46: ...46 9 2 2 Noise Filter Printed Circuit Board 9 2 2 1 CU S9NKV...
Page 47: ...47 9 2 2 2 CU S28NKV...