CompHz = Freq. A × Freq. H + Freq. C
Example Calculation:
Model No.: XE9CK
Operation Mode: Cooling
When Intake Air Temperature - Internal setting Temperature:
1.5°C
CompHz
=
Freq. A × Freq. H + Freq. C
=
1.9 × 20 + 1.0
=
39 Hz (It cuts down less than a decimal point)
Cooling & Soft Dry
XE9CK
XE12CK
Freq. A Freq. C Freq. A Freq. C
Low Load (Freq. H
10)
0.9
11.0
0.9
11.0
High Load (Freq. H > 10)
1.9
1.0
1.9
0.7
Heating
XE9CK
XE12CK
Freq. A Freq. C Freq. A Freq. C
Low Load (Freq. H
12)
1.4
10.6
1.4
10.6
High Load (Freq. H > 12)
2.2
1.0
2.1
1.8
Freq. Range
XE9CK
XE12CK
Cooling
Fc
39
52
Operation Range
12 ~ 86
12 ~ 102
Heating
Fh
56
69
Operation Range
14 ~ 128
14 ~ 128
8.1.2. Compressor Operation Frequency
Zone
Intake Air Temperature - Internal Setting Temperature (°C)
Freq. H
Cooling
Soft Dry
Heating
Cooling
Soft Dry
Heating
Remark
XE9CK XE12CK XE9CK XE12CK XE9CK XE12CK
1
-2.0
-3.0
1.0
2
1
5
5
1
1
2
-1.5
-2.5
0.5
2
5
10
10
3
8
3
-1.0
-2.0
0.0
4
8
10
10
6
13
4
-0.5
-1.5
-0.5
9
12
10
12
11
18
5
0.0
-1.0
-1.0
11
14
12
14
15
23
6
0.5
-0.5
-1.5
14
18
12
17
18
27
7
1.0
0.0
-2.0
17
22
14
17
21
30
8
1.5
0.5
-2.5
20
27
14
20
25
32
Fc, Fh
9
2.0
1.0
-3.0
20
27
16
24
25
32
Fc, Fh
10
2.5
1.5
-3.5
20
27
20
27
25
32
Fc, Fh
11
Nil
Nil
-4.0
Nil
Nil
Nil
Nil
25
32
Fh
12
Nil
Nil
-4.5
Nil
Nil
Nil
Nil
25
32
Fh
Operating Frequency Calculation Formula:
Remarks:
When Freq. H is equal to 20 (XE9CK), 27 (XE12CK) for cooling, 25 (XE9CK), 32 (XE12CK) for heating or above, the Comp.
may run at the freq. higher than Fc or Fh up to max. freq. operation.
Best Amenity Control
Every 90s (Cooling), 120s (Heating) maintain same zone Freq. H + 1 until Fc, Fh.
8.1.3. Cooling Operation
8.1.3.1. Thermostat control
•
•
•
•
Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5°C.
•
•
•
•
Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF
point.
17
CS-XE9CKE CU-XE9CKE / CS-XE12CKE CU-XE12CKE
Summary of Contents for CS-XE9CKE
Page 10: ...4 Dimensions 10 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 11: ...11 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 12: ...5 Refrigeration Cycle Diagram 12 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 13: ...6 Block Diagram 13 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 14: ...7 Wiring Diagram 14 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 91: ...13 Technical Data 91 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 92: ...92 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 104: ...104 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 105: ...How to use electronic circuit diagram 105 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 106: ...18 1 REMOTE CONTROL 106 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...