TROUBLESHOOTING

The following symptoms do not indicate malfunction.

SYMPTOM

CAUSE

Mist emerges from indoor unit.

► •  Condensation effect due to cooling process.

Water flowing sound during operation.

► •  Refrigerant flow inside the unit.

The room has a peculiar odour.

► •  This may due to damp smell emitted by the wall, carpet, 

furniture or clothing.

Indoor fan stops occasionally during automatic fan speed 

setting.

► •  This helps to remove the surrounding odours.

Operation is delayed a few minutes after restart.

► •  The delay is a protection to the unit’s compressor.

Outdoor unit emits water/steam.

► •  Condensation or evaporation occurs on pipes.

The unit operates automatically when power is resumed 

after a power failure.

► •  It is the Auto Restart function of the unit. Operation will 

be restarted automatically under the previous operation 

mode and air flow direction when power is resumed as 

the operation is not stopped by remote control.

Indoor fan stops occasionally during heating operation.

► •  To avoid unintended cooling effect.

Power indicator blinks before the unit is switched on.

► •  This is a preliminary step in preparation for the operation 

when the ON timer has been set.

Cracking sound during operation. 

► •  Changes of temperature cause the expansion/

contraction of the unit.

Check the following before calling for servicing.

SYMPTOM

CHECK

Heating/Cooling operation is not working efficiently.

► •  Set the temperature correctly.

•  Close all doors and windows.

•  Clean or replace the filters.

•  Clear any obstruction at the air inlet and air outlet vents.

Noisy during operation.

► •  Check if the unit has been installed at an incline.

•  Close the front panel properly.

Remote control does not work.

(Display is dim or transmission signal is weak.)

► •  Insert the batteries correctly.

•  Replace weak batteries.

The unit does not work.

► •  Check if the circuit breaker is tripped.

•  Check if timers have been set.

The unit does not receive the signal from the remote 

control.

► •  Make sure the receiver not obstructed.

•  Certain fluorescent lights may interfere with signal 

transmitter. Please consult authorized dealer.

The unit stops and the timer indicator blinks.

Use remote control to retrieve error code.

CHECK ERROR RESET RESET

SELECT

SET/CANCEL

QUIET

POWERFUL

/

A

B

1

Press for 5

seconds.

3

Press for 5 seconds 

to quit checking.

2

Press until you hear 

beep sound, then jot 

down the error code.

Note:

•  For certain error, you may 

restart the unit with limited 

operation with 4 beeps 

during operation starts.

4

  Turn the unit off and reveal the error code to authorized dealer.

PH005413 F567885 All.indb   13

2011-2-23   15:12:22

Summary of Contents for CS-YE9MKE

Page 1: ...r Unit Outdoor Unit S PA7GKD U PA7GKD S PA9GKD U PA9GKD S PA12GKD U PA12GKD Prin ted in Chin a F56 788 5 F10 08 0 0 MO DE AUT O COO L FAN DRY Sele ct the desi red mod e Sele ccio ne el mod o dese ado...

Page 2: ...INFORMATION 62 67 PRODUCT SPECIFICATION 68 QUICK GUIDE BACK COVER ENGLISH Thank you for purchasing Panasonic Air Conditioner NOTE The illustrations in this manual are for explanation purposes only an...

Page 3: ...16 11 16 11 HEATING Maximum 30 24 18 Minimum 16 5 6 DBT Dry bulb temperature WBT Wet bulb temperature NOTICE This model is not suitable for 24 hours non stopping operation in heating mode below 5 C W...

Page 4: ...al parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Do not install the unit in a potentially explosive or flammable atmos...

Page 5: ...used for a long period of time New batteries of the same type must be inserted following the polarity stated POWER SUPPLY Do not pull the cord to disconnect the plug to prevent electric shock WARNING...

Page 6: ...nks during preheating COOL mode To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode DRY mode To dehumidify the environment Unit operates...

Page 7: ...is mode of timer can only be set while the air conditioner is in operation DELAY ON AND OFF TIMER For example to start the air conditioner 7 hours later and stop 10 hours later 1 To select the Delay O...

Page 8: ...trol is misplaced or malfunction Action Mode Press once Auto Press and hold until 1 beep is heard then release Cooling Press and hold until you hear double beep sound then release Heating Press the bu...

Page 9: ...been set Cracking sound during operation Changes of temperature cause the expansion contraction of the unit Check the following before calling for servicing SYMPTOM CHECK Heating Cooling operation is...

Page 10: ...e Level JIS C 9612 70 dB A dB A 40 40 42 42 46 46 Conditions 1m Distance Max cooling heating operation 47 48 48 50 50 52 Sound power level dB A 56 56 58 58 62 62 63 64 64 66 66 68 Air Circulation m3 m...

Page 11: ...69...

Page 12: ...MEMO...

Page 13: ...MEMO...

Page 14: ...de Preparaci n Del Mando A Distancia Vorbereitung der Fernbedienung Telecomando Operazioni Preliminari Afstandsbediening voorbereiding Prepara o Do Controlo Remoto 2 1 3 1 Remove the battery cover Ret...

Reviews: