54
-
ALL MODELS
A Board Waveforms - Formas de Onda de la Tarjeta A
All Models -- To-
dos los Modelos
1.3V p-p [20
µ
s]
TPA5 (VIDEO)
1
1.40V p-p [20
µ
s]
(B OUT)
A11-3
5
28V p-p [5ms]
IC451-13 (PUMP-UP)
9
112V p-p [5ms]
Q551-Collector H Out
13
9.20V p-p [20
µ
s]
V IN
IC451-2
6
5.52V p-p [5ms]
IC001-44 (H PULSE)
10
14
276V p-p [20
µ
s]
IC801-1
1.68V p-p [20
µ
s]
A11-1 (R OUT)
3
1.32V p-p [20
µ
s]
V DRIVE
IC451-7
7
3.12V p-p [5ms]
IC001-43 (FBT PULSE)
11
2.90V p-p [20
µ
s]
IC801-5
15
4
1.44V p-p [20
µ
s]
A11-2 (G OUT)
48V p-p [20
µ
s]
IC451-12 V OUT
8
164V p-p [5ms]
Q501-Collector H Drive
12
IC001 PIN 35
A/D C OSC
2
14.20MHz X’tal
NOTA DE SEGURIDAD
LOS DIAGRAMAS ELÉCTRICOS INCLUYEN CARACTERÍSTICAS
ESPECIALES MUY IMPORTANTES PARA LA PROTECCIÓN
CONTRA RAYOS-X, QUEMADURAS Y DESCARGAS
ELÉCTRICAS. CUANDO SE DE SERVICIO ES IMPORTANTE
USAR PARA REEMPLAZO DE COMPONENTES CRITICOS,
SOLO PARTES ESPECIFICADAS POR EL FABRICANTES. LOS
COMPONENTES CRITICOS ESTAN SEÑALADOS EN LOS
DIAGRAMAS POR EL SIMBOLO
.
IMPORTANT SAFETY NOTICE
THIS SCHEMATIC DIAGRAM INCORPORATES SPECIAL FEATURES
THAT ARE IMPORTANT FOR PROTECTION FROM X-RADIATION, FIRE
AND ELECTRICAL SHOCK HAZARDS. WHEN SERVICING IT IS
ESSENTIAL THAT ONLY MANUFACTURERS SPECIFIED PARTS BE
USED FOR THE CRITICAL COMPONENTS DESIGNATED WITH A
IN
THE SCHEMATIC.
Medición de Formas de Onda
1.
Un símbolo como
indica el punto
para medir una señal. (La medición
puede hacerse en el punto con
mayor accesibilidad, siempre que
sea común al indicado.)
2.
Se midieron utilizando un
generador con formato NTSC
conectado a la terminal de la
antena. (Patrón de 8 Barras de
Colores EAI, formato NTSC de 100
IREs para el Blanco y 7.5 IREs
para el Negro.)
3.
Los ajustes de usuario de los
Menus PICTURE y AUDIO se
normalizaron. Posteriormente el
nivel de volumen se ajusta al
mínimo.
4.
Las formas de onda de Video y
Color fueron tomadas con un
osciloscopio de banda alta y con un
punta de prueba de baja
capacitancia (10 a 1). La forma y
amplitud de las ondas puede variar
según el tipo de osciloscopio que
se utilice y sus características.
5.
El símbolo de tierra que aparece
junto al número de la forma de
onda, indica que se utiliza conexión
a Tierra Caliente en el extremo
negativo de la punta de prueba.
PRECAUCION: Si no se utiliza la
conexión a la tierra adecuada, se
obtendrán mediciones equivocadas
y podría dañar el equipo de
medición.
Waveform Measurements
1.
indicates waveform measurement.
(Measurement can be taken at the
best accessible location in common
to the indicated point.)
2.
Taken with an NTSC signal generator
connected to the antenna terminal.
(NTSC color bar pattern of 8 bars of
EIA colors, 100 IRE white and 7.5
IRE black.)
3.
Customer Controls (Picture/Audio
Menu) are set to Normalize. Volume
is set to “MIN”.
4.
All video and color waveforms are
taken with a wideband scope and
a probe with low capacitance (10
to 1). Shape and peak altitudes
may vary depending on the type
of Oscilloscope used and its
settings.
5.
Ground symbol shown on
waveform number indicates (Hot)
ground lead connection of the
Oscilloscope.
CAUTION: Incorrect ground
connection of the test equipment will
result in erroneous readings.
3
Notas de los Diagramas
1.
Las Resistencias son de Carbón de 1/4W, a
menos que se indique otra característica.
2.
Los Capacitores son de Cerámica para 50V, a
menos que se indique otra característica.
3.
El valor indicado de las Bobinas es la
inductancia expresada en
µ
H.
4.
Los puntos de prueba en la terminal de algún
componente son indicados por Los puntos
de prueba fuera de los componentes se
indican con .
5.
Los componentes señalados con el símbolo
son considerados componentes críticos y
deben ser reemplazados sólo con las partes
especificadas por el fabricante.
6.
(LINEA GRUESA) indica las líneas de
alimentación de los Voltajes B+.
7.
Los diagramas eléctricos están sujetos a
cambio sin previo aviso.
8.
El símbolo
indica que es una conexión a
Tierra Caliente y el símbolo
indica
conexión a Tierra Fría.
NOTA: Los demas símbolos de componentes
incluidos son usados con fines de
diseño.
Schematic Notes
1.
Resistors are carbon 1/4W unless noted
otherwise.
2.
Capacitors are ceramic 50V unless noted
otherwise.
3.
Coil value notes is inductance in
µ
H.
4.
Test point indicated by ; Test point but
no pin .
5.
Components indicated with
are critical
parts and replacement should be made
with manufacture specified replacement
parts only.
6.
(BOLD LINE) indicates the
route of B+ supply.
7.
The schematic diagrams are current at
the time of printing and are subject to
change without notice.
8.
Ground symbol
indicates HOT
GROUND CONNECTION;
indicates COLD GROUND.
Note: All other component
symbols are used for engineering
design purposes.
Summary of Contents for CT-20R6CE