62
Indoor Unit
Outdoor Unit
Model
CS-RE9JKE-1
CU-RE9JKE-1
CS-RE12JKE-1
CU-RE12JKE-1
CS-RE15JKE-1
CU-RE15JKE-1
COOL
HEAT
COOL
HEAT
COOL
HEAT
Single, 230V, 50Hz
Single, 230V, 50Hz
Single, 230V, 50Hz
Power/Current
[kW]
0.700
0.820
1.010
1.120
1.260
1.385
[A]
3.30
3.70
4.70
5.20
6.00
6.30
Refrigerant
[k
g
]
R410A
0.850
R410A
0.970
R410A
1.000
Cooling Capacity
[kW]
2.500
3.500
4.200
Heating Capacity
[kW]
3.300
4.250
5.000
Noise Level
JIS C 9612
[<70 dB(A)]
[dB(A)]
42
42
42
42
46
46
Conditions
1m Distance
Max. cooling/
heating
operation
47
48
48
50
50
51
Sound power
level
[dB(A)]
58
58
58
58
62
62
63
64
64
66
66
67
Air Circulation
[m
3
/min.]
12.5
12.5
12.6
13.3
14.0
15.6
k
g
Product Weight
[k
g
]
9.0
9.0
9.0
24
28
29
Dimensions (L x W x H)
[mm]
848 × 204 × 290
780 × 289 × 540
PRODUCT SPECIFICATION
Test conditions
1.
Temperature (
°C
)
Indoor
Outdoor
*DBT
*WBT
*DBT
*WBT
COOLING
27
19
35
24
HEATING
20
12
7
6
2. Standard piping length: 7.5 m (Includes Indoor Unit piping length).
F567311 Book.indb 62
F567311 Book.indb 62
2010-02-05 3:32:55.MD
2010-02-05 3:32:55.MD
Summary of Contents for CU-RE9JKE-1
Page 32: ...32 Panasonic 32 33 34 35 36 37 56 61 62...
Page 33: ...33 Ni Cd ELCB RCD C DBT WBT DBT WBT 32 23 43 26 16 11 16 11 30 24 18 16 5 6 24 5 C 5 C DBT WBT...
Page 36: ...36 1 2 3 4 5 6 7 AUTO OFF ON 1 8 10 9 2 6 5 7 1 4 3 9 8 pH7 40 C...
Page 38: ...38 Panasonic 38 39 40 41 42 43 56 61 62...
Page 63: ...63...