8
Compact Photoelectric Sensor
CX-400
SERIES Ver.2
ORDER GUIDE
Basic type
(Without operation mode switch and sensitivity adjuster. Cable is 0.5 m
1.640 ft
long.)
Type
Appearance
Sensing range
Model No.(Note 1)
Output
operation
Emitting
element
NPN output
PNP output
Thru-beam
10 m
32.808 ft
CX-411A-C05 CX-411A-P-C05
Light-ON
Red LED
CX-411B-C05 CX-411B-P-C05
Dark-ON
Long sensing range
15 m
49.213 ft
CX-412A-C05 CX-412A-P-C05
Light-ON
Infrared
LED
CX-412B-C05 CX-412B-P-C05
Dark-ON
Retroreflective
With polarizing
filters
3 m
9.843 ft
(Note 3)
CX-491A-C05-Y CX-491A-P-C05-Y
Light-ON
Red LED
CX-491B-C05-Y CX-491B-P-C05-Y
Dark-ON
NOTE: Mounting bracket is not supplied with the sensor. Please select from the range of optional sensor mounting brackets.
Notes: 1) The model No. with “
E
” shown on the label affixed to the thru-beam type sensor is the emitter, “
D
” shown on the label is the receiver.
2)
The reflector is an option. The sensing range of the leflector is specified for the
RF-230
.
3)
The sensing range of the retroreflective type sensor is specified for the
RF-230
(optional) reflector (p.
10
). The sensing range represents the
actual
sensing range of the sensor. The sensing range : A of the table below may vary depending on the shape of sensing object. Be sure to
check the
operation with the actual sensing object.
Optional (Note 2)
Setting range
of the reflector: B
Sensing
object
Sensing
range: A
Sensor
Reflector
(Optional)
CX-491
□
A
0 to 3 m
0 to 9.843 ft
B
0.1 to 3 m
0.328 to 9.843 ft