background image

14

ENGLISH

Change the
programmed
time of
system OFF
p 1 to 7:00
p.m.

6

Press the PROGRAM CANCEL-

ING BUTTON, and cancel the pro-
grammed time.  If you press it
again, display returns to the original
state.  Press the TIMER ON BUTTON
to finalize the cancellation.

Shift to the
programmed
time of
system start
2.

Set the
programmed
time of
system start 2
to program
cancellation.

In the same procedure, cancel the programmed time
of system off 2.

B.  Cancel the whole

7

Press the BUTTON FOR SE-

LECTING DAYS OF A WEEK, and
shift to the day of the week to be
canceled.  Then, press the HOLIDAY
SETTING BUTTON; the display
“OFF” appears at the top of the
particular day of the week.  The
programmed time is canceled.  If
you press the button again, the
display returns to the original state.

Shift the day
of the week to
Thursday to
set as a
holiday.

8

Press the PROGRAMMING

START BUTTON.  The program
setting is now finished.

Notes)

Unless the button is pressed within 20
minutes, the display will automatically
revert back to the original state.  In this
case, setting contents to the point
where the TIMER ON BUTTON (or
HOLIDAY SETTING BUTTON or
BUTTON FOR COPYING PROGRAM
OF PREVIOUS DAY) is pressed will
only take effect.

To continue the change/cancellation, do
not press the PROGRAMMING START
BUTTON until all change/cancellation
are completed.

The operation controlled by timer is
executed even while the program is
being set.

MANUAL OPERATION
(Fig. 6)

This schedule timer enables the operation/stop by
pressing the UNIFIED OPERATION/STOP BUTTON in
addition to the operation controlled by timer (opera-
tion/stop according to the programmed time) at any
time.

Press the UNIFIED OPERATION

BUTTON, and the OPERATION
LAMP turns on.

Press the UNIFIED STOP BUT-

TON, and the OPERATION LAMP is
turned off.

Notes)

The operation automatically stops according to the
programmed time of system off even during the
manual operation.  In the meantime, the operation
starts automatically according to the programmed
time of system start even during the stop of
operation.

If the unit is used in conjunction with other optional
controllers for centralized control, the OPERATION
LAMP of the unit that is not under operation control
may be turned on or off a few minutes behind
schedule.  This shows that the signal is being
exchanged, and does not indicate any failure.

NO.

NO.

CLOCK

OFF OFF

AM

MON TUE WED THU FRI SAT SUN

ON

OFF

PM

1

2

3

4

5

6

7

FRI

5

PM

SET

SET 1

PM

SET

SET 2

ON

OFF

PM

NO.

NO.

CLOCK

OFF OFF

AM

MON TUE WED THU FRI SAT SUN

ON

OFF

PM

1

2

3

4

5

6

7

FRI

5

PM

SET

SET1

PM

SET

SET2

ON

OFF

PM

NO.

NO.

CLOCK

OFF OFF

AM

MON TUE WED THU FRI SAT SUN

ON

OFF

PM

1

2

3

4

5

6

7

FRI

5

PM

SET

SET 1

PM

SET

SET 2

ON

OFF

AM PM

NO.

NO.

CLOCK

OFF OFF

MON TUE WED THU FRI SAT SUN

ON

OFF

PM

1

2

3

4

5

6

7

FRI

5

SET

SET 1

SET

SET 2

ON

OFF

Summary of Contents for CZ-01ESW11P

Page 1: ...OPERATION MANUAL PACKAGED AIR CONDITIONER SCHEDULE TIMER MOdel No CZ 01ESW11P ENGLISH ESPAÑOL ITALIANO NEDERLANDS DEUTSCH FRANÇAIS Before operating this set please read these instructions completely ...

Page 2: ...ion controlled by programmed time Operating time and stopping time can be set to the minute by each day of the week The operating and stopping patterns can also be set in schedule accord ing to the time slot given twice a day in tune with the uses Unified Operation Stop By using this schedule timer the unified operation stop of the indoor unit can be executed manually regardless of the No of progr...

Page 3: ...y of the week and time DISPLAY CLOCK AM AM PM MON TUE WED THU FRI SAT SUN 1 2 3 4 5 6 7 PRO GRAMMED TIME OF SYSTEM START Displays the time programmed to start DISPLAY OFF AM PM PROGRAMMED TIME OF SYSTEM OFF Displays the time programmed to stop TIME NO BUTTON See page 13 16 CLOCK ADJUSTING BUTTON Press this button to set the present time PROGRAMMING START BUTTON Press this button to set or check th...

Page 4: ...he TIMER ON BUTTON the moment the time signal of TV radio telephone etc is heard The mark flashes and the clock starts Notes The clock used is of 12 hour type When you turn power supply on the system may display for about one minute and not start to operate after all the liquid crystal displays appear at a time If the CLOCK ADJUSTING BUTTON is pressed by mistake press it again to return to the ori...

Page 5: ...eturns to the original state Set Saturday and Sunday as holidays 1 Press the PROGRAMMING START BUTTON Programming is available The display PROGRAM START appears and the display of days of a week flashes 2 Press the TIME No BUTTON and select the desired number Note Unless used in conjunction with the central remote controller The TIME No is not displayed and can not be selected Select the TIME No 5...

Page 6: ...ady The display PROGRAM START appears and the display of days of a week flashes 2 Press the TIME No BUTTON and select the desired No Select the time No 3 3 Press the BUTTON FOR SE LECTING DAYS OF A WEEK and set the day of the week to be changed The set No of programmed time of the day of the week is displayed Set the day to Wednesday A Change cancel partially 4 Press the TIMER ON BUTTON and change...

Page 7: ...hange cancellation are completed The operation controlled by timer is executed even while the program is being set MANUAL OPERATION Fig 6 This schedule timer enables the operation stop by pressing the UNIFIED OPERATION STOP BUTTON in addition to the operation controlled by timer opera tion stop according to the programmed time at any time Press the UNIFIED OPERATION BUTTON and the OPERATION LAMP t...

Page 8: ...dule timer is provided with the malfunction diagnosing function The malfunction code flashes if there occurs any malfunction in communication etc between and among the optional controllers for centralized control In addition the operation lamp also flashes if there occurs any malfunction in communication with the indoor unit Check the contents of the display and contact your Panasonic dealer becau...

Page 9: ...3VA10582 6A EM01A045 0110 HT Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global ...