background image

2

CONTENTS

Safety Precautions ...................................................Cover
Speci

fi

 cations .................................................................. 2

Dimensions (Part Names) ............................................... 2
Caution for Network Connection...................................... 2
Installation Precautions ................................................... 2

Installation Location ................................................. 2
General Precautions on Wiring ............................... 2

Mounting .......................................................................... 3

Mounting Position .................................................... 3
How to Mount (Control box) .................................... 3

Wiring .............................................................................. 3

Power Supply Wiring ............................................... 3
Inter-Unit Control Wiring .......................................... 3
External I/O Wiring .................................................. 3
LAN Cable ............................................................... 3

Basic Wiring Diagram .............................................. 3
How to Attach the Ring Pressure Terminal .............. 4
Connecting Wiring ................................................... 4

Connecting to External Equipment .................................. 4
Setting ............................................................................. 5

Preparation before Setting .......................................... 5
Adaptor Setting ............................................................ 6
Air Conditioner Setting  ............................................... 6
Pulse Meter Setting ..................................................... 7
Network Setting ........................................................... 7
Preparation before Operation ...................................... 7

Test Operation  .................................................Back cover

Speci

fi

 cations

Model No.

CZ-CFUSCC1

Dimensions (mm)

<H> 255 × <W> 275 × <D> 80

Weight

1.9 k

g

Temperature/
Humidity range

0 °C to 40 °C /
20 % to 80 % (no condensation) 

Rated voltage/
Rated frequency

Single phase 
100-240 V ~ 50/60 Hz 

Power consumption

Max. 15 W

Number of connectable 
units

Indoor unit - Up to 64 units per link*
Outdoor unit - Up to 30 units per link

*: The number of indoor units includes the Interface Adaptor.

Supplied accessories

Installation Instructions

(1)

License List Disc

(1)

*  Wiring are not included (

fi

 eld supplied item).

Dimensions 

(Part Names)

180

44.5

44.5

221

275

255

(mm)

80

235

LAN

Caution for Network Connection

When connecting to Internet, implement security 
measures against illegal access from outside. 
For detailed connection and setup method, consult the 
network administrator.

Installation Precautions

 

Installation Location

 

Avoid the following locations for installation. 

•  Under direct sunlight    
•  Location near heat source
•  Location where the controller will be splashed with water or 

affected by dampness or humidity

• Uneven surface
•  Location that is subject to excessive vibration or physical 

impacts. (Fixing screws may come off, and the controller 
may drop.)

 

Install the controller away from any sources of 
electrical noise.

 

Install the controller to the locations where is suitable 
to the temperature for using or environment.

 

General Precautions on Wiring

 

Regulations on wire diameters differ from locality to 
locality.
For 

fi

 eld wiring rules, please refer to your LOCAL 

ELECTRICAL CODES before beginning.
You must ensure that installation complies with all 
relevant rules and regulations.

 

Use the 

fi

 eld supplied wiring with at least 1 mm in 

thickness of insulation part including the sheath.

 

Connect all wiring tightly to prevent the terminal 
board from loosening when the wiring connection 
part is pulled by an external force. (Otherwise, 

fi

 re or 

overheating may occur.)

 

Do not bury the inter-unit control wiring in the ground.

 

Do not store the power supply wiring and other wiring 
in the same metal tube or bundle them together. 
(An operational error from noise may occur.)

Symbols on the controller

 

 This symbol refers to “Protective earth”.

 

 This symbol refers to “Caution of Electrostatic”.

   

  This symbol refers to “ON (power)”.

   

  This symbol refers to “OFF (power)”.

CZ-CFUSCC1̲工説̲E.indd   2

CZ-CFUSCC1̲工説̲E.indd   2

2016/02/17   15:50:03

2016/02/17   15:50:03

Summary of Contents for CZ-CFUSCC1

Page 1: ...or death This controller is strongly recommended to be installed with Earth Leakage Circuit Breaker ELCB or Residual Current Device RCD Otherwise it may cause electrical shock and fire in case of equipment breakdown or insulation breakdown Earth Leakage Circuit Breaker ELCB must be incorporated in the fixed wiring in accordance with the wiring regulations The Earth Leakage Circuit Breaker ELCB mus...

Page 2: ...od consult the network administrator Installation Precautions Installation Location Avoid the following locations for installation Under direct sunlight Location near heat source Location where the controller will be splashed with water or affected by dampness or humidity Uneven surface Location that is subject to excessive vibration or physical impacts Fixing screws may come off and the controlle...

Page 3: ...H05RN F or H07RN F which conform to CENELEC HAR rating specifications or use the wiring based on IEC standard 60245 IEC57 60245 IEC66 Total Wire Length 30 m or less Inter Unit Control Wiring Type of wiring Use a flexible shield wiring of 0 5 to 2 mm2 Total Wire Length 1000 m or less Number of connectable units and devices Up to total of 100 units and devices can be connected Indoor unit Up to 64 u...

Page 4: ...oltage DC5 V 10 Contact allowable current Max 10 mA Pulse input 1 Pi1 8 Pulse input 2 Pi2 9 Pulse input 3 Pi3 10 Common COM 7 COM Pulse width 30 msec or more 100 msec or more Pulse interval 1 sec or more Connecting Wiring When connecting external equipment refer to the Connecting to external equipment section below U1 U2 0 1 2 3 4 5 6 20 U1 U2 TB1 TB2 Power supply wiring Power supply terminal boar...

Page 5: ...tion section back cover page 5 Start up the PC and set if the network settings as follows IP address 192 168 1 100 Subnet mask 255 255 255 0 Default gateway 192 168 1 254 6 Enter the following URL in the Web browser and access the cloud adaptor https 192 168 1 1 Recommended Web browser specifications Internet Explorer IE 11 The login screen appears If the login screen does not appear Check if the ...

Page 6: ... and the number of detected units correspond with each other If some of the indoor units are not displayed unexpected indoor units are displayed Check if wiring is properly done or the address setting for air conditioners is correct After correction redo from step 2 4 Enter the central address To assign manually Select the central address text box of the indoor unit on the A C Unit List screen and...

Page 7: ...ctions 1 2 When DHCP is used in the network environment Add a check mark for DHCP Enabled When other than the above Remove the check mark for DHCP Enabled and enter IP address Subnet mask and Default gateway of the cloud adaptor 2 3 When the DNS server information can be automatically obtained in the current environment Add a check mark for Obtain DNS server address automatically When other than t...

Page 8: ...Orange Red Green Lighting Blinking slow once per about 2 seconds Blinking fast once per about 1 second Off LED Status and Solution The cloud adaptor is in the maintenance mode page 7 After maintenance change it to the operation mode Communication failure Both Link 1 and 2 Check if the inter unit control wiring between the air conditioners and the cloud adaptor is correct Both Link 1 and 2 Communic...

Reviews: