Optional Controller
Manual of Controller
2
- 13
1. Timer Remote Controller (CZ-RTC4)
23
(EN)
ECONA
VI Function
Using the remote controller
, you can switch the ECONA
VI function ON/OFF
.
1
Press [ECONA
VI] to ON the
ECONA
VI function.
*
When ECONA
VI is enabled,
will appear
.
A
1 / 2
2
Press [ECONA
VI] to OFF
.
*
When the indoor unit is stopped,
will disappear
.
ON/OFF setting of ECONA
VI function
Note
Turn the ECONA
VI function OFF if:
-
You want to maintain the room temperature at a set temperature.
-
You want to keep air conditioner running while nobody is in a room.
-
The sensor fails.
-
Only infants, babies, or people only with disabilities are in the room.
W
ARNING
Do not use the ECONA
VI function in a room with disabled persons or infants only
.
Due to their limited motions, the ECONA
VI sensor may judge no person is present,
causing the indoor unit to stop the operation.
22
(EN)
ECONA
VI Function
This function is available by attaching an optional ECONA
VI sensor
.
The ECONA
VI sensor detects human activity and conserves energy based on the
activity level.
Overview of the ECONA
VI function
High activity
•
Cooling:
Target temperature is the same as the set temperature.
•
Heating:
Target temperature is 1 °C lower than the set temperature.
Low activity
•
Cooling:
Target temperature is 1 °C higher than the set temperature.
•
Heating:
Target temperature is the same as the set temperature.
No one in the room
No one in the room for 20 minutes
•
Cooling:
Target temperature is 2 °C higher than the set temperature.
•
Heating:
Target temperature is 2 °C lower than the set temperature.
No one in the room for 3 hours
•
Cooling:
Cooling will stop and the unit will be in fan only mode.
•
Heating:
Heating will stop and the unit will be in fan only mode.
*
When the sensor detects movements in the room which have been empty
, it will
resume operation to match with the activity level.
Note
Even when target temperature is changed through the ECONA
VI function, the set
temperature shown in the remote controller does not change.
Even when Cooling/Heating is changed to Fan through the ECONA
VI function,
the operation mode shown in the remote controller will still be
Cooling/Heating.
It is possible to choose from the following options for the operation to be performed after a lapse of 3 hours since the room has been empty
.
•
Operates in the Fan mode only
.
•
Stops and resumes operations after human movements are detected
.
•
Stops
and
will
not
resume
operations
even
after
human
movements
are
detected.
•
Continues to operate in the current mode.
If you need to do so, please contact the dealer
.