background image

<Note 1>

  While the unit is in the SWING mode (swing/flap), the flap cannot be stopped in a 

desired position.

<Note 2>

  When Setting OFF is selected, “°C” is displayed on the LCD.

<Note 3>  You can toggle between ON and OFF by pressing ventilation “( ) button” for 4 seconds 

or more.

<Note 4>  If the Heater Max ON/OFF setting is not changed to EP (ON), the setting change will 

not be reflected.

<Note 5>  This is the number of addresses that can be set in the address change mode. Do not 

set it to 07 or above.

Preparation

:   

Turn on the circuit breaker of units and then turn the power on. After the power is turned 

on, remote controller operation is ignored for approx. 1 minute because setting is being 

made. This is not malfunction. (Contents received while setting are disabled.)

1.  To start test operation, press and hold the emergency operation button for 10 seconds.

2.  The indication lamps (OPERATION, TIMER, STANDBY) blink during test operation.

3.  To finish test operation, press and hold the emergency operation button for 10 seconds.

Attention

 

Do not use this mode for purposes other than 

the test operation.  

(To prevent overload of the units)

 

Read the installation instructions supplied with the units.

 

Any of the Heat, Cool and Fan operations can 

only be performed.

 

Temperature cannot be changed.

 

The test operation mode is automatically  

turned off in 60 minutes. 

 

(To prevent continuous test operation) 

 

Outdoor units do not operate for approx. 3 

 

minutes after the power is turned on or  

operation is stopped.

1-7. Test Operation

 When more than 1 receiver is installed in the same room, setting addresses prevents 

interference.

 For how to change addresses of wireless remote controllers, see the operating instructions of 

wireless remote controllers.

 To change the receiver’s address, remove the cover from the receiver’s PCB and set No.1 to 

No.3 of the [003] DIP switch on PCB.

Remote 

Controller 

Address 

Display

Address  Address  Address  Address  Address  Address  Address  ON/OFF 

States

ALL

1

2

3

4

5

6

Position 

of the 

receiver’s 

address 

switch

Receipt is 

possible 

at all 

of the 

address 

positions

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

OFF ON

1-6. Setting Address Switches

1-9. Room Temperature Sensor Settings

 The indoor unit and the wireless remote controller are equipped with 

room temperature sensors. The sensing of room temperature works 

via one of them.

 When the unit is shipped, it is set to the indoor unit. To switch it to the 

remote controller, press the sensor button (the figure on the right) 

inside the remote controller’s cover and then check that Main Sensor 

 on the LCD screen goes off.

<Note>  Be sure to install the remote controller so as to face the 

receiver.

 

If the unit does not receive any room temperature data from 

the remote controller for ten minutes even with its sensing 

function activated, the indoor unit sensor will automatically 

start sensing the room temperature.

Sensor button

1-8. Self-diagnostics table and detected contents

 

The “Alarm Display” shown in the table below expresses the alarm contents displayed when the 

wired remote controller is connected. For how to handle the alarms, see installation instructions 

of indoor units or technical guide.

Detected contents

Indication lamp on the receiver

Alarm Display

O

P

ERATION TIMER STANDBY Blinking

Communication error in the remote 

controller circuit

E01–E03, E08–E14, 

E17, E18

Communication error either in the in/

outdoor operation line or the sub-bus of 

the outdoor unit

E04–E07, E15, E16, 

E19–E31

Operation of indoor protection device

P01, P09–P14

Alternately

Operation of outdoor protection device

P02–P08, P15–P31

Alternately

Error in the indoor thermistor

F01–F03, F10–F11

Alternately

Error in the outdoor thermistor

F04–F09, F12–F28

Alternately

Error in the indoor EEPROM

F29

Simultaneously

Error in the outdoor EEPROM

F30, F31

Simultaneously

Error related to the compressor

H01–H31

Error in indoor settings

L01–L03, L05–L09

Simultaneously

Error in outdoor settings

L04, L10–L31

Simultaneously

Error in the gas heat pump air 

conditioner

A01-A31

Simultaneously

Inconsistency in Cooling/Heating (Including an auto-temp 

setting for a model without auto-temp settings)

Alternately

Oil alarm (Same as operation of outdoor protection device)

Alternately

Test operation

Simultaneously

 

: OFF  

: ON (Illuminated) 

: Blinking (0.5 seconds interval)

1-10. Setting Up Remote Controller Functions

The functions of the wireless remote controller can be set on site.

(These settings are saved in nonvolatile memory in the remote controller. Therefore, the settings 

do not revert to the defaults even when its batteries are changed.)

<Note>  Only service personnel should make the settings because the operation of the air 

conditioner may be affected, depending on the settings made. 

 

Furthermore, making changes to these settings may cause actual operation to deviate 

from what is printed in the Operating Instructions, so be sure to fully explain this to the 

customer.

Making Settings (Do with unit stopped)

(1) Holding down the swing/flap (

) + OFF timer   ( ) + mode select ( ) buttons at the 

same time for 4 or more seconds will open the setting screen. (See figure below.) 

(2) Use the Temperature setting buttons 

/

 ( ) to select the number of the item to be set.

(3) Use the ON timer buttons  /  ( ) to change settings.

(4) The settings are saved with the once/every day button (

). When this is done, the SET 

displayed on the LCD changes from blinking to lighting.

(5) If other settings are to be changed, repeat steps (2) to (4).

(6) When all settings have been made, press the start/stop ( ) button.

Operation procedure and function display

Item 

Number

(1)

(2)

(6)

(3)

(4)

Detected contents

Set Contents

Factory

setting

1 Operation 

Mode

2

Flap Display

           

(No Display)

             (*1)

3 Select Fan 

Speed

         

(No Display)

4

Display of Set 

Temperature 

°F 

 Setting Off (*2)   °C 

°F

5

Time Display

AM/PM 

 24 Hour (No Display)

AM/PM

6 Ventilation Fan 

ON/OFF

OFF (No Display) 

 ON

OFF (*3)

7

Cool temp Max 41 to 95°F (05 to 35°C)

86°F (30°C)

8 Cool temp Min 41 to 95°F (05 to 35°C)

64°F (18°C)

9 Heat temp Max 41 to 95°F (05 to 35°C)

86

°F

 (30°C) 

(*4)

10 Heat temp Min

41 to 95°F (05 to 35°C)

60°F

 (16°C)

11

Dry temp Max 41 to 95°F (05 to 35°C)

86

°F

 (30°C)

12

Dry temp Min

41 to 95°F (05 to 35°C)

64°F

 (18°C)

13

Auto temp Max 41 to 95°F (05 to 35°C)

80

°F

 (27°C)

14 Auto temp Min

41 to 95°F (05 to 35°C)

62°F

 (17°C)

16 Address Setting 

Max Value

00 (ALL only) 

 01 to 031

06(*5)

17

Heat temp Max 

ON/OFF

JP (Heater Max Temp Change 

Off)   EP (ON)

JP

 

 

 

 

 

 

 

 

 

 

   

   

 

   

   

 

1-13. Specifications

Dimensions

(H) 7-11/64” × (W) 2-13/32” × (D) 47/64” 

 

((H)182 mm × (W) 61 mm × (D)18.5 mm)

Weight

140

g

 (Including batteries)

Power Source

Two AAA size batteries

Clock Accuracy

±30 seconds / month (at 77°F (25°C))

1-11. Installing Wireless Remote Controller

Screw the remote control 

holder.

Remote control holder 

Installing the remote 

controller

2

 Press

1

 Insert

 Press 

 at the installation location 

on the wall, and check that normal 

receiving is possible.

 Remove the remote controller from the 

remote control holder.

Installation location for the Wireless Remote Controller

  If a remote controller is to be operated from a remote control holder that is hung on a wall, turn on the lights in 

the room as well as any electrical appliances and then check to make sure the air conditioner works with the 

remote controller in the location where it will be installed. If it works, continue with installation.

  If the main sensor is to be switched from the indoor unit to a remote controller, pay attention to the following 

when installing.

•  Locate where no warm or cold air will affect it.

•  Locate in a place free from direct sunlight.

•  Locate where it will not be affected by any other heat/cold source.

Wireless Remote Controller

Dimensions

(H) 2-9/16” × (W) 5-35/64” × (D) 57/64”  

 

((H) 65 mm × (W)141 mm × (D) 22.5 mm)

Weight

85

g

Power Source

DC16V(supplied from indoor unit)

Receiver

- 6 -

- 7 -

- 5 -

- 8 -

1-12. 

When installing the remote controller onto a wall, etc.

CZ-RWST2U.indd   2

2015-1-7   14:02:06

Reviews: