background image

Save these instructions!
Conservez précieusement ces instructions !
Diese Anleitung aufbewahren!
Conservare le presenti istruzioni!
Guarde estas instruções!

Φυλάξτε αυτές τις οδηγιες!

¡Guarde estas instrucciones!

Сохраните эту инструкцию!
Збережіть ці інструкції!

CZ-RWSU2
CZ-RWST2
CZ-RWSL2

CZ-RWSC2
CZ-RWSY2
CZ-RWSK2

 EN

 ES

 RU

 UK

 FR

 DE

 IT

 GR

 PT

Wireless Remote Control System 

INSTRUCTION MANUAL

Système de télécommande à infrarouge 

MANUEL D’UTILISATION

Drahtloses Fernbedienungssystem 

BEDIENUNGSANLEITUNG

Sistema Telecomando Senza Fili 

MANUALE DI ISTRUZIONI

Sistema de telecomando sem fi os 

MANUAL DE INSTRUÇÕES

Ασύρματο σύστημα τηλεχειριστηριου 

ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ

Sistema de control remoto inalámbrico 

MANUAL DE INSTRUCCIONES

Беспроводная система дистанционного управления 

ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ

Бездротова система дистанційного керування 

ПОСІБНИК КОРИСТУВАЧА

85464609072022

1

2

3

4

5

6

7

8

9

10

12

11

13
14

15
16

REMOTE CONTROL / TÉLÉCOMMANDE / FERNBEDIENUNG / 

TELECOMANDO / TELECOMANDO / 

ΤΗΛΕΧΕΙΡΙΣΤΗΡΙΟ

 / 

CONTROL REMOTO / 

ПУЛЬТ ДИСТАНЦИОННОГО УПРАВЛЕНИЯ

 / 

ПУЛЬТ ДИСТАНЦІЙНОГО КЕРУВАННЯ

Printed in China

Authorized representative in EU
Panasonic Testing Centre 
Panasonic Marketing Europe GmbH
Winsbergring 15, 22525 Hamburg, Germany

00̲Instruction̲cover̲9L.indd   1

00̲Instruction̲cover̲9L.indd   1

2012/09/12   12:41:49

2012/09/12   12:41:49

Summary of Contents for CZ-RWSU2

Page 1: ...de telecomando sem fios MANUAL DE INSTRUÇÕES Ασύρματο σύστημα τηλεχειριστηριου ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ Sistema de control remoto inalámbrico MANUAL DE INSTRUCCIONES Беспроводная система дистанционного управления ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ Бездротова система дистанційного керування ПОСІБНИК КОРИСТУВАЧА 85464609072022 1 2 3 4 5 6 7 8 9 10 12 11 13 14 15 16 REMOTE CONTROL TÉLÉCOMMANDE FERNBEDIENUNG TELECO...

Page 2: ...lo di Comando Painel de comando Πλαίσιο λειτουργίας Panel de operaciones Панель управления Панель керування I II 3 4 5 2 Indoor Unit CZ RWSK2 Appareil intérieur CZ RWSK2 Raumeinheit CZ RWSK2 Apparecchio Interno CZ RWSK2 Unidade interior CZ RWSK2 Εσωτερική μονάδα CZ RWSK2 Unidad interior CZ RWSK2 Внутренний блок CZ RWSK2 Внутрішній блок CZ RWSK2 2 3 4 5 1 CZ RWSY2 CZ RWSU2 00 Instruction cover 9L i...

Page 3: ...r Operation EN 9 7 Adjusting the Wind Direction EN 11 8 Operating Multiple In Outdoor Units Simultaneously EN 12 9 Using the Remote Control EN 13 10 For Best Results EN 13 11 Addresses EN 14 12 Emergency Operation EN 17 13 Miscellaneous Settings EN 19 14 Before Requesting Service EN 20 15 Specifications EN 21 onbun all indb EN 1 onbun all indb EN 1 2012 09 2012 09 ...

Page 4: ...th wet hands Electric shock and damage to the system can result Protect the remote controller from water Damage to the system can result Stop the system and turn the power off if you sense unusual smells or other irregularities Continuing operation when the system is out of order can result in electric shock fire and damage to the system Contact your dealer Do not swallow the battery Moving and Re...

Page 5: ...ng 1 C at a time 11 Filter button CZ RWSC2 Press to turn off the filter lamp on the receiver 12 Mode Select button Press to switch the operation mode 13 Ventilation button Use this when connected to an aftermarket fan Pressing this button starts and stops the fan When the air conditioner is started or stopped the fan starts or stops at the same time appears on the display of the remote control whe...

Page 6: ...n It is also possible to use both in conjunction with a wired remote control sold separately Consult with the dealer where the product was purchased about making the settings Test On switch This is used during service It is not for normal use Test Run On switch This is used during service It is not for normal use 9 Address switch Differentiate between incoming and outgoing signals Note If a heat p...

Page 7: ...used for a long period of time remove the batteries Please dispose of batteries appropriately After changing the batteries follow the procedures on the next page to reset the current time HOW TO REMOVE BATTERIES 1 Remove the cover 2 Press the battery toward the negative end and lift it out by its positive end As shown at right 3 Remove the other battery in the same way Note Dispose of the used bat...

Page 8: ...ess and hold the button the time changes quickly 3 Set the minutes with of the If you press and hold the button the time changes quickly 4 Pressing completes the time setting While you are setting the current time the time display flashes but the colon does not If the buttons are not pressed for three minutes while setting the current time it is set to the displayed time Note When reset is pressed...

Page 9: ...one of the buttons and set the desired temperature Temperature settings cannot be made when in the Fan mode MAX MIN Auto 27 17 Heat 26 16 Dry Cool 30 18 Stop Press When the unit is stopped with the remote control even though the compressor of the outdoor unit stops the fan on the outdoor unit may continue to run for a while Auto Heat Dry Cool Fan Models that only provide the cooling function canno...

Page 10: ...e and the room temperature Dry Operation Depending on the indoor unit used the remote control may have a Dry indicator on its display even though the unit does not have the Dry function Same as cooler operation When the room temperature approaches the temperature setting the unit continues to start up or stop automatically When the drying mode stops operating the indoor unit s fan blows a gentle b...

Page 11: ...ither of the or and while the time is being displayed if you press again a scheduled time can be set The time last set on the timer is displayed indicates time to change the batteries 2 Press either of the or and set the timer to the desired time Every time you press the time changes in 10 minute increments If you press and hold the button the time changes quickly 3 After setting the timer if you ...

Page 12: ...r again Canceling a timer setting If you press CANCEL the timer setting is canceled If you wish to cancel the setting for either the or the timer press or the desired timer and when the scheduled time is displayed press CANCEL Using the same timer setting every day If you press for 2 or more seconds is displayed and the ON timer or the OFF timer will operate the unit at the same time every day If ...

Page 13: ...arts swinging after the heating standby mode is released but the display on the remote control indicates Auto Flap during standby heating as well CZ RWSU2 CZ RWST2 CZ RWSL2 CZ RWSY2 Indoor Unit CZ RWSK2 Setting the Wind Direction While the unit is operating every time you press the direction the flap faces changes Setting Flap to Swing If you press to set the flap up down wind direction plate in i...

Page 14: ...ded Models Wall Models Please refer to Setting the Wind Direction and Stopping Flap Swing 8 Operating Multiple In Outdoor Units Simultaneously Group control works well for providing air conditioning to one large room with more than one air conditioning units One remote control can operate up to eight indoor units All the indoor units have identical settings Set temperature sensing to the indoor un...

Page 15: ... with rapid start fluorescent lighting inverter lights plasma displays LCD televisions monitor etc For more information please contact the dealer where the product was purchased Wall Mount Use Press from the location you wish to mount the remote and make sure the signal is received correctly Pull the remote control forward to remove it 10 For Best Results Don t get the remote control too far away ...

Page 16: ...volatile memory in the remote control so even when its batteries are changed the settings do not have to be made again 1 CZ RWST2 is of receivers Inside the indoor unit CZ RWSL2 is of an operation panel Inside the indoor unit Checking Addresses When you press on the remote control its current address is shown in the display If this address corresponds to the address of a receiver 2 the buzzer soun...

Page 17: ...es not matter 123 456 123 456 For 1 2 and 3 set the switch on the left and for 4 5 and 6 to the right CZ RWSL2 Position of the operation panel s inside indoor unit address switch The position of the receiver s address switch does not matter For 1 2 and 3 set the switch on the left and for 4 5 and 6 to the right CZ RWSC2 Position of the Receiver s Address Switch The position of the receiver s addre...

Page 18: ...zzer will sound and the address of the indoor unit will change to the address displayed on the remote control 5 If you press Emergency Operation of the indoor unit once the lamps on the indoor unit s display will turn off Note Please do not hold the Emergency Operation button of the indoor unit down while the indoor unit s display lamps are blinking one after another Make sure to operate while the...

Page 19: ...door unit and Indoor Unit CZ RWSK2 is of its front panel CZ RWST2 Start Stop Indoor Unit CZ RWSK2 Start Stop CZ RWSU2 CZ RWST2 CZ RWSY2 Indoor Unit CZ RWSK2 Start press Emergency Operation of the receiver If the indoor temperature is 24 C or greater when the unit starts running it will act as a cooler If the indoor temperature is less than 24 C when the unit starts running it will act as a heater ...

Page 20: ...l act as a cooler If the indoor temperature is less than 24 C when the unit starts running it will act as a heater 2 If you press the wind direction automatically oscillates up and down Stop press Emergency Operation of the receiver again 2 1 CZ RWSL2 CZ RWSC2 1 2 Note The Test Run On and Test On switches are for use when the unit is installed and test run It is not for normal use If the Normal St...

Page 21: ...ired settings How to Operate While holding down the buttons below every time is pressed the remote control s display changes Whatever is being displayed when you release is set Setting Item Operation Button Setting Content Remote Control Display Remote control operation mode display setting when is pressed Press while pressing Heat Pump with Auto Heat Pump without Auto Dedicated air conditioner Cl...

Page 22: ...9 is displayed on the remote control when the unit is stopped An error has occurred in the non volatile memory Please contact your sales outlet Although the unit is for air conditioning only either Auto or Heat is indicated in the display Make settings to the remote control s operation mode display See Page EN 19 After putting the batteries in the remote control even when it is operated the displa...

Page 23: ...CZ RWST2 65 mm H X 130 mm W X 22 mm D CZ RWSC2 120 mm H X 70 mm W X 13 mm D CZ RWSY2 108 mm H X 108 mm W X 20 mm D Power source 16 V DC Supplied from the terminal strip of the indoor unit s remote control CZ RWSL2 Display Dimensions 37 mm H X 70 mm W X 22 mm D Power source 5 V DC supplied from the operation panel Operation Panel Dimensions 55 mm H X 120 mm W X 16 mm D Power source 16 V DC Supplied...

Reviews: