RAI Baud Rate
Software Version: CPC-AII (all versions); CPC-B Version 1.0 or higher
Address: FF1 2# 2# 10# (0 or 1)#
Description
The baud rate used for the DBS’s internal RAI modem can be set to 300 or
1200 bps. By default, 300 bps is used for remote programming.
Programming
Related Programming
Remote Programming ID Code: FF1 4# (0000-9999)#
Notes
Modem Card Requirement for Remote Programming.
Remote
programming is provided through a modem card installed on the SCC card.
Two versions of the Remote Administration Interface (RAI) modem card are
available: RAI-A and RAI-B. The following table shows the transmission
rate of each card, along with the SCC version with which it can be used:
Table 1-5. RAI Modem Card Compatibility
Restrictions for Two-Cabinet Systems Using Voice Mail.
In dual-cabinet
DBS systems that have a Voice Mail system connected to an analog extension
port, the RAI card’s baud rate must be set to 300 bps. See
Technote 3 (April
1991)
for complete information.
RAI Data Communications Parameters.
When using the RAI card with
CPC-A, set the Serial Port parameters as follows:
• Parity: None
• Data Length: 8 bits
• Stop Bit Length: 1 bit
In CPC-B configurations, the DBS will automatically set these parameters for
the RAI card.
RAI Version/Part No.
Transmission Rate
SCC Compatibility
RAI-A (VB-43706)
300 bps
SCC-A or SCC-B
RAI-B (VB-43707)
300 or 1200 bps
SCC-B only
FF1 2# 2# 10# (0 or 1)#
0=300 bps
1=1200 bps
Summary of Contents for DBS-2.3-400
Page 24: ...Intro 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 46: ...Page 1 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 250: ...Page 2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 364: ...Page 5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 428: ...Page 9 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 434: ...Page 10 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...