Section 400-Programming
Chapter 1. System Programming (FF1)
DBS-2.3/9.2-400
DBS Manual - Revised April 2000
Page 1-91
Door Phone Ring Pattern
Software Version: CPC-AII and CPC-B, Version 7.0 or higher
Address: FF1 2# 9# (DoorPhone)# 6# (0-5)#
Description
This address specifies the ring pattern heard at the extension receiving a door
phone call. This applies to door phones connected to digital extension ports
only (not trunk ports).
This address specifies the
number of seconds
between rings (4 seconds by
default). The ring itself has a fixed duration of approximately 3 seconds.
Programming
Related Programming
Door Phone Ring Timer: FF1 2# 9# (DoorPhone)# 5# (0-15)#
Notes
Reset Requirement.
If changing the Ring Pattern setting, activate the change
by unplugging the door phone from its port and plugging it back in.
FF1 2# 9# (1-4)# 6# (0-5)#
Door Phone Number
(1-4)
Number of Seconds Between Rings:
0=Rings one time only (no repeat ringing)
1=4 seconds between rings
2=6 seconds between rings
3=8 seconds between rings
4=10 seconds between rings
5=12 seconds between rings