Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-92
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
Door Opener Relay Timer
Software Version: CPC-AII and CPC-B, Version 7.0 or higher
Address: FF1 2# 9# (DoorPhone)# 7# (0-5)#
Description
Use this address to determine the number of seconds a “buzzing” (unlocked)
door will remain unlocked for the visitor to enter the building (4 seconds by
default). This applies to door phones connected to digital extension ports
only (not trunk ports).
This Relay Timer begins immediately after an extension enters the
appropriate codes (#3*, #3 NNNN *, #3 XXX *, or #3 XXX NNNN *) to
unlock the door.
Programming
Related Programming
Door Opener Access Code Required: FF1 2# 1# 40# (0 or 1)#
Door Opener Access Code: FF1 2# 9# (1-4)# 3# (0000-9999)#
FF1 2# 9# (1-4)# 7# (0-5)#
Door Phone Number
(1-4)
Number of Seconds Door Will Remain Open:
0=2 seconds
1=4 seconds (default)
2=6 seconds
3=8 seconds
4=10 seconds
5=12 seconds