Section 400-Programming
Chapter 1. System Programming (FF1)
DBS-2.3/9.2-400
DBS Manual - Revised April 2000
Page 1-97
Attendant Transfer Recall Timer for CO Calls
Software Version: All Versions
Address: FF1 3# 4# (0-12)#
Description
When an Attendant phone transfers a trunk call to an extension or hunt group,
the transferred call will recall to the Attendant if it is not answered. This
timer determines how long a transferred trunk call will go unanswered before
it recalls (20 seconds by default).
Programming
Table 1-11. Attendant Transfer Recall Timer values for CO calls
Related Programming
Attendant Transfer Recall Timer for Intercom Calls: FF1 3# 24# (0-12)#
Setting
Value
0
No recall
1
20 seconds
2
40 seconds
3
60 seconds
4
80 seconds
5
100 seconds
6
120 seconds
7
140 seconds
8
160 seconds
9
180 seconds
10
200 seconds
11
220 seconds
12
240 seconds
FF1 3# 4# (0-12)#
Attendant Transfer Recall Timer setting for CO calls
Default:
1 (20 seconds)
(see table below)