Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-106
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
CO Flash Timer
Software Version: All Versions
Address: FF1 3# 13# (0-15)#
Description
A DBS phone user can press the FLASH
key to disconnect from and then
reseize a CO loop-start trunk (this operation is called a “flash”). Pressing the
REDIAL key also performs a flash before automatically redialing a phone
number.
This CO Flash Timer determines how long the flash will last if FLASH or
REDIAL is depressed (1 second by default).
Exceptions
: If the FLASH key is pressed
and held down,
the flash signal will
last as long as the key is pressed. (The flash generated by pressing REDIAL
is always controlled by the CO Flash Timer, regardless of how long REDIAL
is held down.) Also, if you are using a PBX or Centrex line, the FLASH key
will place the call on hold.
Programming
Table 1-20. CO Flash Timer values
Setting
Value
0
No flash
1
.2 seconds
2
.3 seconds
3
.4 seconds
4
.5 seconds
5
.6 seconds
6
.7 seconds
7
.8 seconds
8
.9 seconds
9
1 second
FF1 3# 13# (0-15)#
CO Flash Timer setting
Default:
9 (1 second)
(see table below)
NOTE:
Settings 11 to 15 are available with CPC-A Version 3.3
or higher, and CPC-AII/B 5.0 or higher. These settings require
Loop-Start Trunk Card VB-43510A or VB-43511A.
Summary of Contents for DBS-2.3-400
Page 24: ...Intro 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 46: ...Page 1 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 250: ...Page 2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 364: ...Page 5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 428: ...Page 9 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 434: ...Page 10 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...