Section 400-Programming
Chapter 1. System Programming (FF1)
DBS-2.3/9.2-400
DBS Manual - Revised April 2000
Page 1-107
Related Programming
PBX Flash Timer: FF1 3# 18# (0-10)#
Auto Flash Redial: FF1 2# 1# 6# (0 or 1)#
Trunk Circuit Type: FF2 (Trunk)# 21# (0 or 1)#
Dialing Restriction During Inbound Trunk Calls for TRS Types 3-6: FF7 1#
2# (0 or 1)#
Notes
Circuit Card Requirements.
Timer settings 11-15 are only available with
the loop-start trunk card (Part No. VB-43510A or VB-43511A).
Phone Type Restriction.
The FLASH key function applies only to digital and
digital single-line telephones.
Trunk Type Restriction.
This timer only applies to loop-start trunks.
FLASH and REDIAL Restriction.
FLASH and REDIAL features are not
available with ground-start trunks. See
Technote 13 (March 1992)
for further
information.
SLT Flash Operation.
Single-line telephones must press the hookswitch and
dial “87” to activate this feature.
Using FLASH Key With PBX or Centrex Lines.
If you are using a PBX or
Centrex line, the FLASH key places the call on hold. See
PBX Flash Timer
address (FF1 3# 18#) for more information.
10
1.1 seconds
11
1.5 seconds
12
2 seconds
13
2.5 seconds
14
3.0 seconds
15
3.5 seconds
Summary of Contents for DBS-2.3-400
Page 24: ...Intro 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 46: ...Page 1 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 250: ...Page 2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 364: ...Page 5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 428: ...Page 9 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 434: ...Page 10 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...