Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-108
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
SLT Onhook Flash Timer
Software Version: All Versions
Address: FF1 3# 14# (0-6)#
Description
This timer determines how long an SLT user must hold down the switchhook
before the DBS recognizes a hookflash (200 ms by default). This address
also includes a setting that prevents hookflashes from being performed on
SLTs.
If you change this setting, you must turn the system off, then back on to
activate the change.
Programming
Table 1-21. SLT Onhook Flash Timer values
Notes
Power-Cycling Requirement.
In order for changes to this program to take
effect, the system must be turned off, then back on.
Address
Setting
Flash Treatment
No Detection
Valid Flash
Disconnect
0
Less than 200 ms
200 to 500 ms
Greater than 500 ms
1
Less than 200 ms
200 to 700 ms
Greater than 700 ms
2
Less than 200 ms
200 to 1000 ms
Greater than 1000 ms
3
Less than 200 ms
200 to 1200 ms
Greater than 1200 ms
4
Less than 200 ms
200 to 1500 ms
Greater than 1500 ms
5
Less than 200 ms
None
Greater than 200 ms
6
Less than 200 ms
200-500 ms
Greater than 500 ms
FF1 3# 14# (0-6)#
SLT Onhook Flash Timer setting
Default:
4 (valid flash=200 to 1500 ms)
(see table below)
Summary of Contents for DBS-2.3-400
Page 24: ...Intro 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 46: ...Page 1 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 250: ...Page 2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 364: ...Page 5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 428: ...Page 9 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 434: ...Page 10 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...