Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-148
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
Disconnect Timer
Software Version: CPC-B Version 4.0 or higher
Address:
FF1 8# 4# 2# 2# (0-12)#
Description
Determines how long the DBS waits before sending a disconnect signal from
the T1 to the CO (200 ms by default).
NOTE:
The CO Disconnect Timer (FF2 Trunk# 18# 0-15#) determines how
long the system waits to
receive
a disconnect signal from the CO.
Programming
Table 1-38. T1 Disconnect Timer values
Notes
Power-Cycling Requirement.
For changes to this parameter to take effect,
the system must be turned off, then back on.
Setting
Value
0
150 ms
1
200 ms
2
250 ms
3
300 ms
4
400 ms
5
500 ms
6
1000 ms
7
1500 ms
8
2000 ms
9
2500 ms
10
3000 ms
11
3500 ms
12
Off (DBS does not automatically
send a disconnect signal)
FF1 8# 4# 2# 2# (0-12)#
Disconnect Timer setting
Default:
1 (200 ms)
(see table below)