Section 400-Programming
Chapter 1. System Programming (FF1)
DBS-2.3/9.2-400
DBS Manual - Revised April 2000
Page 1-149
Guard Timer
Software Version: CPC-B Version 4.0 or higher
Address:
FF1 8# 4# 2# 3# (0-15)#
Description
Determines how long the system guards a T1 circuit (1200 ms by default).
When the DBS “guards” a circuit, it holds the circuit after it has been released
to make sure the previous call is properly disconnected. This means the
channel cannot be used for another call until the Guard Timer has expired.
Programming
Table 1-39. T1 Guard Timer values
Notes
Power-Cycling Requirement.
For changes to this parameter to take effect,
the system must be turned off, then back on.
Setting
Value
0
200 ms
1
300 ms
2
400 ms
3
500 ms
4
800 ms
5
1000 ms
6
1200 ms
7
1400 ms
8
1600 ms
9
1800 ms
10
2000 ms
11
2200 ms
12
2400 ms
13
2600 ms
14
2800 ms
15
3000 ms
FF1 8# 4# 2# 3# (0-15)#
Guard Timer setting
Default:
6 (1200 ms)
(see table below)