Section 400-Programming
Chapter 1. System Programming (FF1)
DBS-2.3/9.2-400
DBS Manual - Revised April 2000
Page 1-159
Notes
Example Digital Pad Adjustment.
If calls to SLTs via a master T1 have low
volume levels, the pad level for connections from the master T1 to all SLTs
can be changed.
By default, the pad level for connections from the master T1 to all SLTs is 16
(or -2 dB). To raise the volume by 2 dB, change the pad value to 0 (or 0 dB)
by programming the following:
FF1 8# 4# 3# 2# 5# 0#
where:
2#
is the circuit type for SLTs;
5#
is the circuit type for T1 in the master cabinet; and
0#
is the pad number for 0 dB loss/gain.